13
normal condition.
d) Check the oil return pipe to see if it is in normal
condition.
e) Check the pressure of the automatic stop.
f) Check the unloading valve to see if it is deflating or
not when the machine stopped. Check also the
exhaust temperature.
g) Check the voltage and electric current to see if they
are in normal condition.
h) Check, clean and replace the safety valve if
necessary.
i) Record the voltage, current, air pressure, exhaust
temperature and oil level every day and take notes
of the working time, maintenance status and
abnormalities per shift.
ATTENTION:
Don’t open oil drain ball valve until five
minutes after stopping the compressor.
1. Open the oil drain valve slightly and drain off any
water from the bottom of the oil Tank. Drain fluid until
water stops flowing and only oil flows. (See Fig. 9.2 )
2. The oil level must be above the upper red line after
the compressor is shut off and has been stopped for
thirty minutes. The oil level when the compressor is
running must be between the upper and lower red line
indicated on the Oil Level Site Glass. (See Fig. 9.3 )
3. Fill with PowerCool Synthetic Air Compressor
Lubricant if necessary and inspect the O-Ring on the Oil
Fill Plug before tightening.
START UP PROCEDURE
:
1. Make sure any installed valves are open.
2. Turn on the Power; The LCD Display will show a
welcoming message and then the Display will indicate
Compressor’s
STATE: NORMAL STOP.
3. Press the
ON
Button; The compressor will begin
the Delayed Start countdown, once the delayed time is
reached the Compressor will start up automatically. If
necessary pressing the
STOP
Button during the delayed
Start Countdown will Stop the delayed start Countdown
and place the Compressor in the
STATE: NORMAL
STOP.
(The compressor will not be able to be restarted
for at least ninety seconds (default) after it has been
stopped for any reason.)
4. After starting up: Watch the pressure on the control
panel. Check operating temperature and the general
conditions inside the compressor.
The Compressor will run in the
STATE: AUTO LOADING
until the preset system pressure is reached. The
Minimum Oil Level
when stopped
and cold
Minimum Oil Level
while running
Fig. 9.3
Fig. 9.2
Summary of Contents for RS7580H603
Page 34: ...34 Frequent ...
Page 35: ...35 ...
Page 36: ...36 RS7580H603 SCREW COMPRESSOR PARTS LIST ...
Page 37: ...37 RS7580H603 SCREW COMPRESSOR PARTS LIST ...
Page 38: ...38 RS7580H603 SCREW COMPRESSOR PARTS LIST ...
Page 40: ...40 RS7580H603 SCREW COMPRESSOR PARTS LIST ...
Page 41: ...41 RS7580H603 SCREW COMPRESSOR PARTS LIST ...
Page 42: ...42 RS7580H603 COMPRESSOR ELECTRIC DIAGRAM ...
Page 43: ...43 RS7580H603 COMPRESSOR ELECTRIC DIAGRAM ...
Page 44: ...44 RS7580H603 COMPRESSOR ELECTRIC DIAGRAM ...
Page 45: ...45 ...
Page 48: ......