____________________________________________________________________________
89000004-101
KI 300 Installation Manual
Rev 1
Page 4-9
© Honeywell International Inc. Do not copy without express permission of Honeywell.
Each pages
’
value is internally stored when the corresponding page is exited, not upon exit of the last
page.
4.7.3
Setup Pages
A total of 29 setup pages are available as follows:
Table 4-2: KI 300 Setup Parameters
Setup Page
Purpose
Min
Value
Max
Value
Increment
Reference
Section
Pitch Trim
Used to adjust for various panel tilts.
-45°
+45°
0.1°
4.7.3.1
Roll Trim
Used to adjust for minor variations in roll.
-5°
+5°
0.1°
4.7.3.1
Panel Type
Hard Mount / Float Mount
Hard
Float
n/a
4.7.3.2
ADC Display
Used to enable/disable Airspeed and Altitude
tapes (IAS/BCA, IAS Only, BCA Only, No
IAS/BCA)
n/a
n/a
n/a
4.7.3.3
ADC Calibration
Enter Air Data Computer (ADC) Calibration?
No skips to Vs0 menu item.
No
Yes
n/a
4.7.3.4
IAS Trim @
30 knots
Used to adjust for minor variations in airspeed
at 30 knots.
-50
+50
1kt or mph 4.7.3.4
IAS Trim @ 400
knots
Used to adjust for minor variations in airspeed
at 400 knots.
-50
+50
1kt or mph 4.7.3.4
ALT Trim @
0 ft
Used to adjust for minor variations in altitude
at 0 ft.
-999 ft
+999 ft
1ft
4.7.3.4
ALT Trim @
35,000 ft
Used to adjust for minor variations in altitude
at 35,000 ft.
-999 ft
+999 ft
1ft
4.7.3.4
Vs0
Used to set Vs0 band on IAS indicator.
0
400
1 kt or mph 4.7.3.5
Vs1
Used to set Vs1 band on IAS indicator.
0
400
1 kt or mph 4.7.3.5
Vfe
Used to set Vfe band on IAS indicator.
0
400
1 kt or mph 4.7.3.5
Vno
Used to set Vno band on IAS indicator.
0
400
1 kt or mph 4.7.3.5
Vne
Used to set Vne band on IAS indicator.
0
400
1 kt or mph 4.7.3.5
Vyse
Used to set Vyse mark on IAS indicator.
0 Disables.
0
400
1 kt or mph 4.7.3.5
Vmc
Used to set Vme mark on IAS indicator.
0 Disables.
0
400
1 kt or mph 4.7.3.5
IAS Units
Used to set units for IAS (KTS or MPH)
n/a
n/a
n/a
4.7.3.6
Baro Units
Used to set baro units (inHg or Mb)
n/a
n/a
n/a
4.7.3.7
Baro Default
Used to set default baro settings (STD, AUTO,
LAST)
n/a
n/a
n/a
4.7.3.8
IVSI Damping
Used to disable display of IVSI, or enable IVSI.
Also used to set the display filtering. (OFF,
0..10 seconds)
0 sec
10 sec
1 sec
4.7.3.9