Figure 4-3 Front and Rear Mounting Bracket
Electrical bonding must be carefully considered when installing the mounting bracket to the instrument
panel, as this is the primary grounding mechanism for High-Intensity Radiated Fields (HIRF) and lighting
protection.
The mounting bracket must remain un-painted and be bonded to the aircraft frame (or equivalent for
composite aircraft) with a resistance of 2.5 milliohms or less. This can be achieved by cleaning and/or
removing paint from the rear side of the instrument panel where the retaining nuts make contact with
the panel structure.
4.4
Wiring Installation
1.
Construct the power and ground lines utilizing aviation grade 22 AWG, non-shielded, stranded
wire.
2.
The power line must be protected by a 2 AMP circuit breaker.
3.
Keep power and ground lines less than 1 meter in length.
The KI 300 is supplied with one 9 pin Sub-D female mating connector and back-shell. The Sub-D
connector uses screw lock assemblies to secure the connector to the unit.