____________________________________________________________________________
89000004-101
KI 300 Installation Manual
Rev 1
Page 4-2
© Honeywell International Inc. Do not copy without express permission of Honeywell.
Figure 4-2 Instrument Cutout
Front and rear mounting brackets adapt the unit connection points to the 3” round instrument hole
cutout. The front bracket is constructed of stainless steel, and should be inspected prior to installation
to insure general flatness. The rear bracket is utilized to fasten the unit to the panel. The supplied
screws and nuts must be used to retain the brackets.
4.3
Mounting Bracket Installation
1.
Inspect the mounting bracket to ensure general flatness and integrity.
2.
Remove any paint from REAR of instrument panel around the nut-to-panel interface points
–
the
mounting bracket must be fully grounded to the instrument panel.
3.
Install the bracket and tighten the four screws and nuts. Ensure that the bracket is level relative
to the aircraft while the nuts are being tightened.
4.
Minor roll error can be corrected by slightly rotating the bracket prior to tightening and during
the configuration of the unit.