CC613-Hxx_D00423_02_M_XXEN/11.2020 15
CC613-Hxx charge controller
4.3
Connectivity
4.3.1 USB configuration interface (CONFIG)
The USB configuration interface (CONFIG) on the front panel of the charge controller is connected to a con-
ventional laptop, PC or tablet computer via a micro USB cable. This interface allows local configuration of the
charge controller. In addition, it enables the installation of software updates (for a configuration description,
refer to chapter "Configuration and testing"). The web interface can be accessed via the IP address
192.168.123.123.
4.3.2 Ethernet interface (depending on the variant)
The charge controller can be connected to an existing Ethernet network via an Ethernet interface. For further
information, refer to chapter "Configuration and testing".
4.3.3 STATUS LED
The "STATUS" LED on the front panel indicates the following system states:
Power on/system not ready for operation
System is starting
System started, not ready for operation yet
System ready for operation
System error
4.3.4 12 V power supply (depending on the variant)
The charge controller is supplied with power from a 12 V main voltage source at the +12 V and 0V connec-
tions.
4.3.5 Contactor connection
The charge controller controls the contactor, which in turn controls the power flow toward the vehicle. The
contactor is controlled via a relay in the charge controller, the contacts of which are rated for 230 V/4 A.
4.3.6 Weld check
By means of the measuring lines WA/WB (terminal designation) an impermissible closing of the contactor con-
tacts, e.g. welding/sticking, can be detected.