20 CC613-Hxx_D00423_02_M_XXEN/11.2020
Configuration and testing
The
Manufacturer
tab of the charging system control interface can be accessed via the URL
http://192.168.123.123/manufacturer. To access this tab, user name and password are required:
• User name: manufacturer
• Password: orange_zone
i
The default passwords should be changed to prevent unauthorised access.
The manufacturer can also change the user passwords and parameters via the
Operator
tab.
Application of changed parameters
Parameter changes are not necessarily applied after submission. To submit all changed parameters, click the
"Save & Restart" button at the bottom of the tab. A message indicating a necessary restart may appear.
I
a
utomatiC
reboot of the charge controller!
In order to ensure perfect functionality, the charge controller
carries out a regular system reboot.
i
After the web configuration interface has been accessed or while a vehicle is connected, the charging point
will suppress system reboots for at least 2 minutes to allow all parameters to be configured.
5.1.2 Factory settings
i
Resetting to factory settings deletes all settings except the serial number.
Click the "Operator Default & Restart" button on
the
Operator
tab to reset changed parameters
of the operator configuration to default.
Click the "Settings Default & Restart" button on
the
Settings
tab to reset changed parameters to
default.
Click the "Manufacturer Default & Restart" button on the
Manufacturer
tab to reset changed parameters of
the manufacturer configuration to default. Click the "Factory Reset & Restart" button to reset the charge con-
troller to factory settings.
5.1.3 Testing and system boot process
After completing the configuration, the charge controller must be tested for operability. This can be done us-
ing a vehicle simulator. The following is checked:
• Successful boot process
• Connection to meter possible (meter configuration)
• Plug locking and unlocking works (depending on the variant)