CC613-Hxx_D00423_02_M_XXEN/11.2020 13
CC613-Hxx charge controller
Legend
A
Connection measuring current transformer (CT)
m
RCD type A
B
12 V supply, PE, Modbus meter, CP, PP
n
Voltage supply DC 12 V
C
2x USB type A (depending on the variant)
o
Measuring current transformer (CT)
with plug
D
Connection Ethernet (depending on the variant)
p
Contactor
F
Configuration interface
q
Type 2 socket-outlet
H
Weld check, relay for contactor control rated for 230 V/4 A
J
Locking (depending on the variant)
L
STATUS LED
Terminal assignment
B
0V
Input 0 V
+ 12V Supply v12 V
PE
Input PE
PE
Input PE
B Mod. Modbus meter B
J
A Mod. Modbus meter A
CP
Control Pilot
A
Actuator A: Locking actuator output negative
PP
Proximity Pilot
B
Actuator B: Locking actuator output positive
HS2 Actuator HS2: Locking input actuator switch
H
WA
Weld check input L1
HS1 Actuator HS1: Locking 12 V output actuator switch
23
Relay 23: Switching contact
contactor
WB
Weld check input N
24
Relay 24: Switching contact
contactor
I
C
aution
!
Switching contact contactor and weld check at terminal H are only suitable for mains voltage
(230 V)!
Not permitted for SELV/PELV voltages.
i
For variants with a permanently attached charging cable, the terminals J for plug locking and the wiring of
the Proximity Pilot (PP) to terminal B are not required.