Technical data
40
CP9xx-Kit_D00399_00_M_XXEN/07.2019
Modbus TCP
Interface/protocol ............................................................................................................................ Ethernet/Modbus TCP
Operating mode ..................................................................................Client for PEM and "third-party devices" assigned
Operating mode .................................................Server for access to process image and for Modbus control commands
SNMP
Versions .....................................................................................................................................................................1, 2c, 3
Devices supported ........................................................Queries to all devices (channels) possible (no trap functionality)
BMS bus
Interface/protocol.............................................................................................................................. RS-485/BMS internal
Operating mode .............................................................................................................................master/slave (master)*
Baud rate................................................................................................................................................................9.6 kbit/s
Cable length......................................................................................................................................................... < 1200 m
Cable: twisted pair, shielded, one end of shield connected to PE ............................recommended: J-Y(St)Y min. 2x0.8
Connection.......................................................................................................... "ABMS", "BBMS" (see plug-in terminal)
Terminating resistor ...........................................120 Ω (0.25 W), can be switched on internally (see plug-in terminal)
Device address .................................................................................................................................................. 1…99 (1)*
Modbus RTU
Interface/protocol.............................................................................................................................. RS-485/Modbus RTU
Operating mode ........................................................................................................................................................master
Baud rate ................................................................................................................................................. 9.6…57.6 kbit/s
Cable length......................................................................................................................................................... ≤ 1200 m
Cable: twisted pair, shielded, one end of shield connected to PE ............................recommended: J-Y(St)Y min. 2x0.8
Connection.............................................................................................................. "AMB", "BMB" (see plug-in terminal)
Terminating resistor ...........................................120 Ω (0.25 W), can be switched on internally (see plug-in terminal)
Supported Modbus RTU slave addresses .............................................................................................................. 2…247
Digital inputs (1-12)
Number............................................................................................................................................................................. 12
Galvanic separation ......................................................................................................................................................... yes
Operating mode ................................................................................selectable for each input: active-high or active-low
Factory setting ....................................................................................................................................................active-high
Voltage range (high)............................................................................................................................... AC/DC 10…30 V
Voltage range (low) .................................................................................................................................... AC/DC 0…2 V
Max. Current per Channel (AC/DC ≤ 30 V ..................................................................................................................8 mA
Connection....................................................................................................................plug-in terminal: (1;1;2;…12;12)
Maximum cable length ....................................................................................................................................... ≤ 1000 m
Switching element
Operating mode ................................................................................................................ N/C operation / N/O operation
Function .......................................................................................................................................................programmable
Electrical endurance under rated operating conditions, number of cycles .............................................................10,000
Contact data acc. to IEC 60947-5-1:
Utilisation category ................................................................................................................ AC-13 AC-14 DC-12
Rated operational voltage.................................................................................................... AC 24 V AC 24 V DC 24 V
Rated operational current ....................................................................................................AC 2 A AC 2 A DC 2 A
Minimum contact rating .................................................................................................................1 mA at AC/DC > 10 V
Connection..............................................................................................................................plug-in terminal: (11;12;14)
Buzzer
Buzzer message............................................................. can be acknowledged, adoption of characteristics of new value
Buzzer interval .................................................................................................................................................configurable
Buzzer frequency .............................................................................................................................................configurable
Buzzer repetition ..............................................................................................................................................configurable
Audio
Line IN............................................................................................................... STEREO signal input via 3.5 mm jack plug
Line OUT..................................................................................Output to a STEREO playback device via 3.5 mm jack plug
Summary of Contents for B95061094
Page 8: ...Important information 8 CP9xx Kit_D00399_00_M_XXEN 07 2019...
Page 10: ...Safety instructions 10 CP9xx Kit_D00399_00_M_XXEN 07 2019...
Page 14: ...Product description 14 CP9xx Kit_D00399_00_M_XXEN 07 2019...
Page 22: ...Installation connection and commissioning CP9xx Kit 22 CP9xx Kit_D00399_00_M_XXEN 07 2019...