![background image](http://html1.mh-extra.com/html/belson/mobile-ii/mobile-ii_instruction-sheet_2730451007.webp)
5
V CONNECTING AND DISCONNECTING YOUR TANK
CONNECTING TANK
Mount the L.P. tank to the support bracket with (4) 3/8”-16 x 3/4” hex head bolts. The Belson fuel
tank will only draw vapor fumes while lying in the horizontal position as shown on the drawing.
Never attempt to use the Belson LP fuel tank in the vertical position or outside of its support
hoops.
Connect regulator to tank. Be sure arrow on regulator is in direction of gas flow. Connect one end of
flexible gas hose to regulator and the swivel end to the manifold assembly. Carefully tighten all
fittings.
The regulator supplied with your liquid propane gas grill is set for 11” wc and is for use with propane
gas only. This regulator and the factory supplied hose assembly
must be
used when operating your
grill. If replacement of the hose and / or regulator becomes necessary, factory specified parts are
required.
IMPORTANT!
Red arrow at top front of the tank and tank valve handle must point up!
If frosting occurs on the regulator, the LP tank is not properly mounted or the tank is over filled.
(See Section IV "
PROPANE TANK HANDLING AND FILLING"
Pg. 4)
DISCONNECTING TANK
Slowly close the liquid propane tank valve and allow burners to burn all gas from the
manifold system. Turn burner control knobs to 'OFF' position. Make sure no open
flames are present, and allow unit to cool. Disconnect the regulator and insert the
safety plug into the tank. Follow all warnings pertaining to storage of propane tanks.
(See Section IV "
PROPANE TANK STORAGE, HANDLING AND FILLING"
Pg. 4)
www.belson.com