WARNINGS
WARNING
THE WATER FROM THE STEAM DRAIN OUTLET IS EXTREMELY
HOT AND MAY CAUSE SERIOUS BURNS.
PG. 7
NOTICE
Left rear drain point is provided. Route to a floor drain. A 1”
gap must be provided between oven drain and floor drain.
PG. 7
WARNING
WIRES ENTERING THE DISCONNECT MAY STILL BE LIVE EVEN
WHEN THE SWITCH IS TURNED OFF. SWITCH THE MAIN BREAKER
AT THE WALL TO “OFF” WHEN SERVICING THE OVEN
PG. 8
CAUTION
TO REDUCE THE RISK OF FIRE, THE APPLIANCE IS TO BE
MOUNTED ON FLOORS OF NON-COMBUSTIBLE CONSTRUCTION
WITH NONCOMBUSTABLE FLOORING AND SURFACE FINISH AND
WITH NO COMBUSTIBLE MATERIAL AGAINST THE UNDERSIDE
THEREOF, OR ON NONCOMBUSTABLE SLABS OR ARCHES
HAVING NO COMBUSTIBLE MATERIAL AGAINST THE UNDERSIDE.
SUCH CONSTRUCTION SHALL EXTEND A MINIMUM OF 12-INCHES
BEYOND THE EQUIPMENT ON ALL SIDES. See fig. 1
PG. 10
Fig. 1
Floor
Construction