 ID.No.     Parts No.                       Description                                                               QTY

    1       1A07R4A0 Wall Plate

    2       ECPE34A0    

    2       1A04BYA0    

Arm Mounting Bracket

    3       1A0389A0     Chassis

    4       1A03Z6A0     Power PC Board

    5        ---------          End Cap Screw(M6 x 15)

(small)

Wall Plate(large (option)

)

    6       1A0387A0     Restriction Plate

    7       1A0386A0     Front Panel

    8        ---------          Screw for Front Panel( 3 x 6 )

    9       1E01J8A0      Main Power Switch

   10      1A0385A0     Front Cover

   11      1A04JFA0      Side Cover

   12      1A04BXA0    Horizontal Arm Frame

   13      ECLJ36A0     Arm End Cap

   14      ECQR70C0    Arm Bottom Cover

   15      1P01CXA0    Wire Harness in Horizontal Arm (800mm)

             1P01CYA0    Wire Harness in Horizontal Arm (1000mm)

             1P01CZA0    Wire Harness in Horizontal Arm (300mm)

             1P01D0A0    Wire Harness in Horizontal Arm (500mm)

             1P01D1A0    Wire Harness in Horizontal Arm (650mm)

   16       ---------          Lag Screw( 9 x 75)

   17       ---------          Machine Bolt(M8 x 20)

   18      ECPR44B0    Retaining Bolt(M6 x 35)

   19      ECLS06B0    Brake Plug

   20       ---------         Brake Screw(M6 x 6)

   21      ECLS11B0    Brake Spring

 22        ---------          Stopper Screw(M6) 

 23       ---------          Screw for Chassis(M4 x 10)

 24      ECNR24A0   Hole plug for End Cap

 25       ---------          Screw for Chassis(M4 x 6)

 26       ---------          Screw for Cover(M3 x 8)

 27      1A037WA0    Chassis for Sub Controller

 28      1A037VA0     Front Panel for Sub Controller

 29      ECQR58A0   Protector for Timer PC Board

 30      1A03L4A0     Timer PC Board

 31      ECQR68A0   Hook for Hand Exposure Switch(Option)

 32       ---------          Hand Exposure Switch Assembly(Option)

 33       ---------          Tapping Screw(Option)

 34       ---------          Front Cover screw for Sub Controller(M3 x 8)

 35       ---------          Wood Screw( 4.1 x 20)

 36      1A03CKA0    Switch sheet  

 37      1P01CEA0     Horizontal Arm Assmbly(800mm)

           1P01CFA0     Horizontal Arm Assmbly(1000mm)

           1P01B7A0     Horizontal Arm Assmbly(300mm)

           1P01CGA0    Horizontal Arm Assmbly(500mm)

           1P01CHA0    Horizontal Arm Assmbly(650mm)

 38      1P01CJA0     Main Controller Assembly

 39      1P01CLA0    Sub Controller Assembly

 40      1A04JGA0     Hook for Side Cover

 41      ---------           Screw for Hook(M4 x 6)

 42      EEMV52B0   

 43      EHLN17A0   

Thrust Washer

-

3

0

-

 ID.No.     Parts No.                       Description                                                                QTY

T1

F

D

P

70

a b

4 7

INC

Mats

φ

φ

φ

Exposure Switch wise Wire

M

ats

M

ats

M

ats

M

ats

Ma

ts

Mats

Ma

ts

Ma

ts

Mats

Mats

APPENDIX 

3

 : PARTS IDENTIFICATION

   

[ 1 ] 

CONTROLLER ASSEMBLY

C

T5

T2

T3

T4

kV

60

mA

INC

CUS 

&

 PM

CUS 

&

 PM

MLR

OCC

MLR

BW

31

33

34

39

32

44

27

35

29

30

28

43

Mats

36

11

11

40

41

45

46

1

2

38

3

4

6

7

9

10

25

8

26

16

23

21

19

20

17

18

19

22

12

13

14

26

15

15

13

37

20

42

Summary of Contents for PHOT-X IIs 505

Page 1: ...nstallation assembly calibration and certification procedures for BELMONT PHOT X IIs 505 dental x ray The instructions contained in this book should be thoroughly read and understood by dealer service...

Page 2: ......

Page 3: ...IDENTIFICATION AND OPERATION 1 MAJOR COMPONENTS AND CONTROL DENTIFICATION 17 2 FUNCTION OF CONTROLS 18 3 OPERATING PROCEDURES 21 4 ESTIMATED AIR KERMA 21 5 OPTIONAL HAND EXPOSURE SWITCH 21 6 ERROR CO...

Page 4: ...utput 60 kV 70 kV 3 mA 6 mA 3 mA 6 mA a Distal end of regular cone 4 6 9 1 5 9 11 8 mGy sec 40 b Distal end of long cone 2 0 4 1 2 6 5 2 mGy sec 40 Data obtained by direct measurement in the useful be...

Page 5: ...Maximum Reach 185 1 15 PHOT X IIs Sub Controller 34 mm Front to Back Box Thickness P 150 178 211 7 7 23 100 6 1 130 1 16 0 1 29 4 85 2 31 50 973 1023 1243 Short Cone Long Cone Cabinet Frame for X ray...

Page 6: ...both B Duty cycle A cool down interval of 30 seconds or more must be allowed between each 1 second exposure a 15 second cool down must be allowed between each 0 5 second exposure This will avoid the a...

Page 7: ...n device Use a flexible cable approved by CEE 13 52 or 53 consists of 0 75 mm2 or 1 mm2 conductors Diameter of the sheath of cable should be 6 7 5 mm diameter Line voltage regulation should be within...

Page 8: ...wing radiation requirements concerning the operator s positioning must be considered The operater must 1 have full view of the patient 2 have means for audio and visual communications with the patient...

Page 9: ...ENTS 2 UNPACKING Unpack the entire contents of the shipping carton Included within the shipping carton are Hardware Quantity Head with Regular Cone 1 Main Controller 1 Screw for chassis M4 x 10 mm 4 S...

Page 10: ...ring matches to the access hole of wall plate template 2 Mark the hole locations for the arm mounting bracket lag screws 3 Use a 3 16 5mm dia drill to make a pilot hole approximately 50mm deep for eac...

Page 11: ...nting bracket Fig 3 5 Insert the cable of horizontal arm into the hole and mount to the arm mounting bracket as shown in Fig 3 5 2 Insert two retaining bolts into the upper threaded holes of the arm m...

Page 12: ...de toward the wall to close Fig 3 9A 2 Install two M3 x 8mm screws into the top of the cover and confirm that the cover is securely attached Fig 3 9B M3x8 Screw Front Cover Front Cover Front Cover Cha...

Page 13: ...3A Note Two ring terminals should not protrude from a chassis plate Fig 3 13A 5 Secure the wires from the balance arm to the bottom cover with the nylon cable clamp to prevent damage from twisting Fig...

Page 14: ...n the band 1 Remove the arm collar screw M4 x 8mm from the arm collar Slide the arm collar upward and temporarily hold it in position with adhesive tape Fig 3 15 2 Open the yoke inside cover of x ray...

Page 15: ...ith the nylon cable clamp Fig 3 18 7 Reattach the yoke inside cover with the screw M4 x 15mm Before closing the cover note the CP values on the CP values label inside of the yoke Fig 3 16 8 Remove arm...

Page 16: ...ler Fig 3 21 Miswiring causes permanent damage to both timer PC board and power PC board 5 If wire length is too long push it back into the access hole of the wall This will prevent mechanical damage...

Page 17: ...ith the tapping screw 3 x 8mm Fig 3 25 Fig 3 23 Hand Exposure Switch Kit Hand Exposure Switch Hook Tapping Screw 3 x 8 Fig 3 24 Connecting Hand Exposure Switch Timer PC Board Front Panel CN3 CN2 CN3 H...

Page 18: ...light tendencies to drift can be corrected by tightening brake screw in horizontal arm Do not tighten beyond what is required to prevent drift 2 BALANCE ARM TENSION ADJUSTMENT 1 Place the balance arm...

Page 19: ...tion Switch 2 Ready Light 11 Film Speed Selection Switch 3 ExposureTimeAdjusting Switch Down 12 Digital Imaging Switch 4 ExposureTimeAdjusting Switch Up 13 kV Selection Switch 5 Tooth Selection Switch...

Page 20: ...GHSUHVVHG PRUH WKDQ VHF XQLW JRHV LQWR RFN 0RGH Q ORFN PRGH WKH RQO IXQFWLRQDO VZLWFK LV WKH SRZHU VZLWFK 7R H LW IURP WKH ORFN PRGH GHSUHVV WKH 7 VZLWFh PRUH WKDQ VHF DJDLQ RQH 7 SH 6HOHFWLRQ 6ZLWFK...

Page 21: ...Q WKH SRVXUH 7LPH LVSOD LQGRZ LWK WKH IDFWRU VSHHG VHWWLQJ G 0 WKH H SRVXUH WLPH EHFRPHV KDOI RI 10 VHWWLQJ As the sensitivity is different according to each manufacturer of digital imaging sensors th...

Page 22: ...13 0 16 0 18 0 22 0 32 0 22 0 25 0 32 0 36 0 50 0 28 0 32 0 40 0 45 0 63 3 0 18 0 22 0 28 0 32 0 45 0 32 0 36 0 45 0 50 0 71 0 40 0 45 0 56 0 63 0 90 6 0 09 0 11 0 13 0 16 0 22 0 16 0 18 0 22 0 25 0...

Page 23: ...ures when the unit is not in XVH 127 I WKH XQLW OHIW RYHU PLQ ZLWKRXW EHLQJ RSHUDWHG DQG WKH 0DLQ 3RZHU 6ZLWFK LV NHSW RQ ILJXUH UXQV WKURXJK WKH SRVXUH 7LPH LVSOD LQGRZ 7KLV GRHV QRW PHDQ WKDW PDOIXQ...

Page 24: ...re than 4 5 mA at 3mA setting or more than 9 mA at 6 mA setting Setting for pre heating time is out of range Tube current is detected during pre heating period Tube current is detected when main power...

Page 25: ...QLQJ ZLWKLQ WKH PDQXIDFWXUH V VSHFLILFDWLRQV DQG UHPDLQV LQ FRPSOLDQFH ZLWK WKH 6WDQGDUG W LV UHVSRQVLELOLW RI WKH RZQHU RI WKH XQLW WR VHH WKDW WKHVH PDLQWHQDQFH FKHFNV DUH correctly performed Any pa...

Page 26: ...re making an exposure check this value to be same as the value stored in the subcontroller 1 Confirm the tube potential compensation CP values for 60kV and for 70kV written on the label attached insid...

Page 27: ...g light is located on the front panel of the sub controller 1 Make an exposure and confirm that the warning light illuminates during the exposure 6 CONFIRMATION OF LINE VOLTAGE REGULATION 1 Make sure...

Page 28: ...ase film speed number until desired number for a setting is displayed 3 To change the b setting from the factory default F 05 push F switch momentarily until the b light illuminates By depressing or s...

Page 29: ...conds Release the switches if the ready light starts to flash 2 bu 2 will be displayed in exposure time display window 3 By depressing either or switch display changes to bu 0 4 Press P switch Patient...

Page 30: ...GE BLUE BROWN BLACK GRAY WHITE ORANGE PURPLE YELLOW BLUE BROWN GRAY RED WHITE BLUE GRAY RED WHITE YELLOW BROWN BLACK BROWN GREEN YELLOW RED BLUE YELLOW BLACK 3 1 2 SWITCH EXP 1 2 3 4 TIMER PC BOARD RE...

Page 31: ...racket to the wall plate are loose find the reason why bolts became loose take counter measure that prevent bolts become loose 6 Dosimetry Save the image that was taken under appropriate conditions as...

Page 32: ...ats Mats Mats Mats APPENDIX 3 PARTS IDENTIFICATION 1 CONTROLLER ASSEMBLY C T5 T2 T3 T4 kV 60 mA INC CUS PM CUS PM MLR OCC MLR BW 31 33 34 39 32 44 27 35 29 30 28 43 Mats 36 11 11 40 41 45 46 1 2 38 3...

Page 33: ...r PC Board 240V Timer PC Board 110V Timer PC Board 100V Timer PC Board 120V Timer PC Board 220V Timer PC Board 230V 31 ECQR68B0 Hook for Hand Exposure Switch Option 32 Hand Exposure Switch Hand Exposu...

Page 34: ...e Inside Cover Screw M4 x 15 1 5 Head Housing Cover Set 1 set 6 Yoke Side Cap 1 7 Yoke Side Cap Screw 3 x 8 1 8 Lock Ring 1 9 Regular Cone 1 10 Long Cone Option 1 11 Rectangular Collimator Option 1 12...

Page 35: ...NOTE...

Page 36: ...Book No 1A0GDSG0 Printed in Japan 2017 04 2 1 1 Higashishinsaibashi Chuo ku Osaka 542 0083 Japan TEL 81 6 6213 5945 TELEFAX 81 6 6212 3680 TAKARA BELMONT CORPORATION NOTE R...

Reviews: