18
>
2
@)81&7,212)&21752/6
0DLQ3RZHU6ZLWFK
3XVKLQJWKHXSSHUVLGHRIWKLVVZLWFKWRWKH21SRVLWLRQHQHUJL]HVWKH[UD\XQLW5HDG\OLJKW
DQGSUHVHOHFWOLJKWVIRUFRQHW\SHILOPRUGLJLWDON9P$DQGSDWLHQWVL]HLOOXPLQDWH
,WLVUHFRPPHQGHGWRNHHSWKLVVZLWFK2))ZKHQWKHXQLWLVQRWLQXVHLQRUGHUWRSUHYHQWDQ
DFFLGHQWDOH[SRVXUH
,03257$177RSUHYHQWWKHULVNRIDQDFFLGHQWDOH[SRVXUHSXVKWKHORZHUVLGH
RIWKLVVZLWFKWRWKH2))SRVLWLRQZKHQWKHXQLWLVQRWLQXVH
5HDG\/LJKW
7KLVOLJKWLOOXPLQDWHVZKHQWKHOLQHYROWDJHLVZLWKLQRSHUDEOHUDQJH
5DWHGOLQHYROWDJH
:KHQWKLVOLJKWLVQRWRQH[SRVXUHFDQQRWEHPDGH
([SRVXUH7LPH$GMXVWLQJ6ZLWFKHV
%\PRPHQWDULO\SXVKLQJWKH RU VZLWFKWKHH[SRVXUHWLPHGLVSOD\HGLQFUHDVHVRU
GHFUHDVHV
E\RQHLQFUHPHQW%\NHHSLQJWKHVZLWFKGHSUHVVHGPRUHVHFWKHH[SRVXUHWLPH
GLVSOD\HGLQFUHDVHVRUGHFUHDVHVFRQWLQXRXVO\XQWLOWKHVZLWFKLVUHOHDVHG
0RGHOKDVWKHIROORZLQJH[SRVXUHWLPHVHWWLQJV
VHF
a
7RRWK6HOHFWLRQ6ZLWFKHV7a7
3XVKLQJRQHRIWKHVHVZLWFKHVVHWVWKHH[SRVXUHWLPHDXWRPDWLFDOO\IRUWKHIROORZLQJ a
7,QFLVRURI0DQGLEOH
7,QFLVRURI0D[LOOD&XVSLG 3UHPRODURI0DQGLEOH
7&XVSLG 3UHPRODURI0D[LOOD0RODUVRI0DQGLEOH%LWHZLQJ
70RODURI0D[LOOD%LWHZLQJ0RODUV
72FFOXVDO
,IWKH7VZLWFK LVGHSUHVVHGPRUHWKDQVHFXQLWJRHVLQWR/RFN0RGH,QORFNPRGH
WKHRQO\IXQFWLRQDOVZLWFKLVWKHSRZHUVZLWFK7RH[LWIURPWKHORFNPRGHGHSUHVVWKH7
VZLWF
h
PRUHWKDQVHFDJDLQ
&RQH7\SH6HOHFWLRQ6ZLWFK
By de
SUHVVLQJWKLVVZLWFKIRU
less than 2 sec.,
selected
cone type can be confimed. If round
cone is
selected, "rnd" is displayed. If
the cone with
rectangular
collimator
is
selected
, "rEC" is
displayed. Depressing
this switch more than 2 sec. changes the cone type by the following order.
Short cone (Round) --> Short cone with r
ectangular
collimator
-->
Long cone (Round)
-->
Long cone with rectangular collimator --> Short cone (Round) --> continued
)LOP6SHHG6HOHFWLRQ6ZLWFK
D 3+27;,,VKDVILOPVSHHGVHWWLQJV)a)
7ZRVSHHGVHWWLQJVDUHSUHVHWDWWKHIDFWRU\D EDQGFDQEHVHOHFWHGZLWKVZLWFK
D )LOPVSHHG1R)HTXLYDOHQWWR,62VSHHGJURXS'RU.RGDN8OWUD6SHHGILOP
E )LOPVSHHG1R)HTXLYDOHQWWR,62V
p
HHGJURXS)(RU.RGDN,Q6LJKWILOP
In
cluding
these two speeds, PHOT-X IIs 505 x-ray can provide 16 different film
VSHHGV
(F.00 ~ F.15) and any two of them can be programmed for easy selection. If doctor
XVHV
a different film speed, or prefers darker (or lighter) radiographs, the new speed can be
programmed as follows. Higher speed settings make films darker. If film speed is
increased by 1, exposure time becomes 25 % longer.
1. Keep the kV selection switch and mA selection switch depressed simultaneously for
more tha
n 3 seconds. Release the switches if the ready light starts to flash.
Summary of Contents for PHOT-X IIs 505