560 - 570mm
547mm
703mm
595mm
550mm
9mm
706
mm
697
mm
Min 550mm
Min
710
mm
12mm gap in
plinth for air intake
Method 3:
Housing unit with internal
height 710mm or more
Note:
You will not need the 4 runners
and 2 trims that are packed with the
oven for this installation.
Remove any fixings that may prevent
entry of the oven into housing, or
obstruct the gas inlet pipe. The
cabinetry should be kept structurally
sound by fixing to adjacent cabinets,
floor or worktop.
Rear
wall
Worktop
space behind
appliance to
be kept clear
min 30mm air gap
required at back of
support shelf
12mm air
gap in top
of plinth
support
shelf
1. When installed in a typical
600mm deep built in housing unit,
the false back should be removed
from the housing unit to provide
the necessary depth for installation.
2. When the false back is removed,
it is normally the case that the
support shelf for the appliance leaves
a gap between the back edge and
the wall of approximately 80mm.
3. If no gap occurs between the back
edge of the shelf and the wall
behind the unit, you must create a
gap of at least 30mm by
shortening the shelf.
Installation Instructions