Method 2:
Housing unit with internal
height less than 710mm
Note:
You will not need the 2 side
trims (687mm long) or the appliance
runners for this installation. You will
need the 2 runners to fix to the
adjacent cabinets.
Before you start - make sure, before
removing the bottom shelf or modifying
the housing unit, that it will remain
structurally sound - eg; by fixing to
adjacent cabinets, floor or worktop.
There must be enough space at the
back of the oven for the gas inlet pipe
to hang clear of any obstructions.
You may have to cut into, or remove,
any rear cross members from the
housing unit too obtain the 550mm
minimum depth.
To obtain the required 710mm height,
you may have to lower or remove the
bottom shelf, remove any cross rails
and reposition brackets.
To fix the runners (if required)
1. Take the side trims, hold it against
the side of the base unit, and use
it to mark off the 687mm from the
top edge of the side unit, to the top
edge for the runner.
Note:
This ensures a 5 - 8mm
clearance from the underside of
the worktop to the top of the
appliance.
2. Measure 50mm from the front
edges of the base units, to mark
the front edge for the runners.
3. Take 6 of the No 8 x 12mm
(Black) chipboard screws and
screw the runners into position the
right way up as shown.
4. If necessary, adjust the height of
the plinth to just below the bottom
edge of the runners.
If you require a replacement fixing kit
please call
0870 458 9961
and
order part number
01 28287 00
.
22
Installation Instructions
27353 00 - Belling GG720 14/6/07 14:59 Page 24