Gas Conversion (ULPG to NG)
- Auxiliary Jet
- Semi-Rapid Jet
- Rapid Jet
-
4kW
Wok Jet
Converting to a different gas type
When converting from ULPG to Natural Gas ensure that the
ULPG test point is removed and replaced with the AGA Approved
NG Regulator supplied in this kit. The test point pressure must be
adjusted to 1.00kPa with the largest burner
operating on maximum flame.
Changing the jets
1. Remove pan supports, burner heads and caps.
2. Use a size 7 socket wrench to unscrew and
remove the jets, replacing them with those
supplied in this kit. Ensure you use the correct
jet for the corresponding burner.
3. Reassemble the burner heads, caps and pan
supports.
4. Fit the Gas type label supplied with this kit next
to the gas connection point and remove the
existing label.
Setting the minimum level
1.
Light one of the burners and turn the tap to
minimum flame.
2.
Remove the corresponding control knob.
3.
Use a thin blade screwdriver to turn the by-pass
screw located in the brass shaft as shown right.
Turn the by-pass screw fully clockwise then turn
it
anti-clockwise
1/4 turn for 4kw wok and 1/8 turn for
dual wok and all other burners.
The result should
be a
small, stable flame which is uniform around
the
entire burner ring. If not, turn the by-pass
screw
anti-clockwise until satisfied with the flame.
4.
Check that the burner does not go out when the
tap is turned quickly from the maximum to the
minimum position.
5.
Repeat for each burner.
If the required gas conversion kit is not supplied with your
appliance, contact
Belling
. Gas Conversion shall only be
undertaken by authorised persons.
The ULPG to NG conversion kit contains...
- NG Regulator
- NG Gas Type label
Ø090mm
Ø1.18mm
Ø1.55mm
Ø1.
8
0mm
24
-
5kW
Wok Jet
Ø
1.80mm, Ø80mm