Technical data
·
·
Electricity supply
220-240V AC (50Hz)
Gas intake connection
1/2" BSP
Auxiliary
Semi Rapid
Rapid
Wok
(4kw)
Injector
(mm)
0.90
1.18
1.55
1.
8
0
Nominal Gas
Consumption
3.90
MJ/h
6.60
MJ/h
1
0.80
MJ/h
1
4.00
MJ/h
Natural Gas
1.0 kPa
Injector
(mm)
0.53
0.70
0.90
1.00
Nominal Gas
Consumption
3
.
30
MJ/h
6.10
MJ/h
10.00 MJ/h
12.20
MJ/h
U
2.75 kPa
LPG
Burner Type
Instructions for installation
This appliance shall be installed only by authorised persons and in
accordance with the manufacturer's installation instructions, local
gas fitting regulations, municipal building codes, electrical wiring
regulations, AS/NZS 5601 - Gas Installations and any other
statutory regulations.
Data Label - The Data Label is located on the bottom of the
appliance. A duplicate Data Label is supplied to adhere in an
accessible area next to the appliance. This appliance is suitable
for Natural Gas and ULPG; ensure that the available gas supply
matches the Data Label and the gas type label.
15
Installation
220-
220-240V/50-
YWWXXXXX
BGH905WSS
45.0MJ/h
45.0MJ/h
220-
220-240V/50-
YWWXXXXX
BGH905WBG
45.0MJ/h
45.0MJ/h
Wok
(5kw)
1.80+0.80
1
7.00
MJ/h
0.90+0.46
12.20
MJ/h