SECTION I: INTRODUCTION

GENERAL INFORMATION  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

RATINGS  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

OPTIONS  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

STANDARD FEATURES  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

MODEL VARIATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

SAFETY PRECAUTIONS  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

SECTION II:  INSTALLATION

DAMAGE DURING SHIPMENT  . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

POSITIONING  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

RESTRAINING DEVICES  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

ELECTRICAL CONNECTION  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

SECTION III:  OPERATING

LIGHTING  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

SHUTDOWN  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

CLEANING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

SECTION IV: MAINTENANCE

WARRANTY REPAIRS  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

PREVENTIVE MAINTENANCE  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

SECTION V:  ORDERING PARTS

ORDERING PARTS  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

WARNING AND OPERATING PLATES . . . . . . . . . . . . . . . . . . . . . . .3

HOT PLATE PARTS LIST  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

HOT PLATE ASSEMBLY  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

SECTION VI:  WIRING DIAGRAMS

HOT PLATE WIRING AND LADDER DIAGRAMS  . . . . . . . . . . .5-11

WARRANTY   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12

CONTENTS:

IMPORTANT:

Keep a copy of your bill of sale. The date on the bill establishes the warranty period should

service be required. If service is performed, it is in your interest to obtain and keep all receipts. Keating 
commercial hot plates are not intended for household use.

The Owner’s Guide provides specific operating instructions for your model. Use the Electric Hot Plate
only as instructed in this Owner’s Guide.

e l e c t r i c H o t P l a t e

0 5 / 1 1

p a r t #   0 374 3 0

RECORD THE MODEL AND SERIAL 

NUMBERS OF THIS ELECTRIC HOT PLATE

IN THE SPACES PROVIDED.

SERIAL NO. ______________________________

MODEL NO. _____________________________

KEEP THESE NUMBERS FOR FUTURE REFERENCE.

*AS CONTINUOUS PRODUCT IMPROVEMENT OCCURS, SPECIFICATIONS MAY BE CHANGED WITHOUT NOTICE.

Summary of Contents for MG-2

Page 1: ...PLATE ASSEMBLY 4 SECTION VI WIRING DIAGRAMS HOT PLATE WIRING AND LADDER DIAGRAMS 5 11 WARRANTY 12 CONTENTS IMPORTANT Keep a copy of your bill of sale The date on the bill establishes the warranty peri...

Page 2: ...ICITY TO THIS UNIT BEFORE IT IS SECURED TO PREVENT TIPPING IMPROPER INSTALLATION ADJUSTMENT ALTERATION SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE INJURY OR DEATH READ THE INSTALLATION OPERATING...

Page 3: ...tion Back 6 0 Right Side 6 0 Left Side 6 0 You must install this appliance at least 16 away from any open flame Adequate clearance for servicing and proper operation must be maintained Your hot plate...

Page 4: ...movement of the appliance IF DISCONNECTION OF THE RESTRAINT IS NECESSARY IT MUST BE RECONNECTED WHEN THE HOT PLATE IS RETURNED TO ITS ORIGINALLY INSTALLED POSITION ELECTRICAL CONNECTION The Keating El...

Page 5: ...ventive maintenance should be done in daily weekly and monthly intervals as necessary Following preventive maintenance procedures will help keep your hot plate working efficiently Proper care and serv...

Page 6: ...INITE CONTROL 2 4 011614 4 INFINITE CONTROL KNOB ONLY 2 4 037587 5 INDICATING LIGHT AMBER 240V 2 4 050255 6 TERMINAL BLOCK NOT SHOWN 208 240 VOLT UNITS 1 2 034381 FOR 480 VOLT UNITS 4 026241 7 CONTACT...

Page 7: ...5 VI WIRING DIAGRAMS MG 2 208 240 VOLT SINGLE PHASE...

Page 8: ...6 MG 2 208 240 VOLT 3 PHASE...

Page 9: ...7 MG 2 480 VOLT SINGLE PHASE WITH RESISTORS FOR 240V HEATING ELEMENTS...

Page 10: ...8 MG 2 480 VOLT 3 PHASE WITHOUT RESISTORS FOR 240V HEATING ELEMENTS...

Page 11: ...9 MG 4 208 240 VOLT SINGLE PHASE...

Page 12: ...10 MG 4 208 240 VOLT 3 PHASE...

Page 13: ...11 MG 4 480 VOLT 3 PHASE WITHOUT RESISTORS FOR 240V HEATING ELEMENTS...

Page 14: ......

Page 15: ...CE COMPANY ________________________________________________________________________________________________ ADDRESS ____________________________________________________________________________________...