Kurt König
Ludwig Wolf
Patrick Klein
4
AUX COMMAND
AUXILIARY COMMAND
No matter what the state of the terminal is: monitoring, call or communication,
this key may action an automation connected to the system: auto access or
garage gate, lighting system etc.
3
ACCES
After the command, the lock is unblocked for 1...10 sec. for the access of the
visitors.
// You cannot grant access without having a prior communication.
ACCESS and
END COMMUNICATION!
Communication
1 STAND-BY
The keys of the outdoor panel and the inhabitants' names are permanently backlit.
2
CALL AND COMMUNICATION
Call duration: maximum 1 min.
Call duration: maximum 1 min.
Touch the key (related to the inhabitant).
The call to the inhabitant is signaled acoustically. You may end the call by pressing
again the key. If the inhabitant answers, communication is initiated.
If access is granted, the panel emits an acoustic signal, and the lock remains
unblocked for maximum 10 seconds. If the inhabitant does not answer, after a
minute, the panel returns to stand-by mode.
7
.3
Use of the outdoor panel
MAINTENANCE
8
The outdoor panels must be kept away from corrosive substances, lime or mechanical shocks.
The terminals must be kept away from water, or any other liquids, mechanical shocks, fumes,
dusts etc.
The components of the system can be cleaned with a piece of soft, cotton cloth.
The optional accumulator connected with the supply control unit will be replaced after the
expiry of its life span. The supply control unit ensures the accumulator's charging, as long as
the accumulator is not defect. The state of the accumulator is indicated by the signals of the
LED S1 and the acoustic warning in case of a defect.
29/92