PROG
STROMVERSORGUNGSEINHEIT (SCU.VDN.BLW)
S2
Video
S1
Audio
EINGANG: 230V Wechselspannung 50Hz, 0.4A
AUSGANG 1: 14V, 2A Gleichspannung (S1)
AUSGANG 2: 14V, 0.5A Gleichspannung (S2)
ACHTUNG! Lebensgefahr,
gerät nicht öffnen!
GEFAHR EINES
STROMSCHL AGS!
SCHLOSSÖFFNUNGSZEIT
(sekunden)
1
6
4
1
0
2
8
3
5
7
9
COMMISIONING OF THE SYSTEM
6
6.1
Description of the supply control unit
TIME:
Lock timing adjustment
The
supply control unit
includes:
Protection lid for connections
Front lid
LED signaling of programming /
Front lid defect within the system
*PROG. : programming button
S2: existence of tension at the +Uv - GNV hubs
S1: presence of tension at the +14V - GND hubs
Protection lid for connections
*
The KIT does not require programming. This button is used only if you add additional
terminals or panels to the system.
AUX Command
(automation)
5.2
Auxiliary command connection (optional)
GND
LA
AUX 2
AUX 1
Relay contact
Maximum switched current
: 1.5 A
5.1
Installation of the electromagnetic lock (optional)
Drive current (DC)
Drive current
electromagnetic lock (DC)
LC2
2 x 0.75 mm
²
cable
BUT
LC
LA/C
LA
supply control unit
LC1
2 x 0.75 mm
²
cable
Alternative current
electromagnetic lock (AC)
BUT
LC
LA/C
LA
Transformer
12 Va.c.
230 Va.c.
supply control unit
Alternative current (AC)
The supply control unit can supply a current of
max. 1A for the supply of the lock.
The tension of +14 V d.c. is present on the LC
hub of the supply control unit.
The connection of a lock actuating button
from the interior of the building will be made
at the BUT and LC hubs of the supply
control unit.