background image

9

1. 

BEA SMP_QX_E

Sub Menu: Program Utilities

Sub Menu: Program Utilities

  PROGRAM UTILITY:          

--  Recall a Program  --

  PROGRAM UTILITY:          

--  Recall a Program  --

 Recall a Program

 01: ARENA VIENNA 

 Recall a Program

 01: ARENA VIENNA 

Seleting ‚Recall a Program‘,  the SMP_QX will suggest the previously used program.

In the given example,  it is program Nr.01 

Should you want to use this program, confirm by ‚Enter‘    

Enter

ESC (quit) 

Enter

 (Enter) to Recall

 01: ARENA VIENNA

 (Enter) to Recall

 01: ARENA VIENNA

Enter

 Loading New Program...

 01: ARENA VIENNA

 Loading New Program...

 01: ARENA VIENNA

  PROGRAM UTILITY:          

--  Recall a Program  --

  PROGRAM UTILITY:          

--  Recall a Program  --

 Recall a Program

 01: ARENA VIENNA 

 Recall a Program

 01: ARENA VIENNA 

Selecting ‚Recall a Program‘,  the SMP_QX will suggest to use the previously  used program.  

 

In the given example, this is program Nr.01.  Should you want to use a 

different program, select this via  

PM1 encoder.

In the given example, programm Nr. 12 (Theater Hamburg) was selected. 

Selecting a previously stored program will load all of its parameters.

Any previously active parameters will be replaced by those of the last loaded program.

  

Enter

ESC (quit) 

PM1

 Recall a Program

 12: Theater Hamburg

 Recall a Program

 12: Theater Hamburg

Enter

 Loading New Program...

 12: Theater Hamburg

 Loading New Program...

 12: Theater Hamburg

 (Enter) to Recall

 12: Theater Hamburg

 (Enter) to Recall

 12: Theater Hamburg

Enter

  PROGRAM UTILITY:          

--  Save a Program  --

  PROGRAM UTILITY:          

--  Save a Program  --

 Save a Program

 01: ARENA VIENNA 

 Save a Program

 01: ARENA VIENNA 

When selecting ‚Save a Program‘,  the SMP_QX will suggest to use the previously  used program 

name and number. 

In the given example, it is program Nr.01. Should you want to use this program, confirm by Enter.

In order to change the program name, use PM1 (cursor) and PM2 (sign)

In the given example, the new name is Open Air Cologne 

Enter

ESC (quit) 

Enter

 (Enter) to Overwrite

 01: ARENA VIENNA

 (Enter) to Overwrite

 01: ARENA VIENNA

Enter

 Set Program Name

 01:  Open Air Cologne

 Set Program Name

 01:  Open Air Cologne

 (Enter) to Save

 01:  Open Air Cologne

 (Enter) to Save

 01:  Open Air Cologne

Enter

 Saving to Memory.....

 01:  Open Air Cologne

 Saving to Memory.....

 01:  Open Air Cologne

Enter

Recall a Program

Recall a Program

Recall a Program

Recall a Program

Save a Program

Save a Program

Summary of Contents for SMP QX Series

Page 1: ...or has been mechanically or electrically damaged or if the personal password of the user has been forgotten No user serviceable parts inside For service refer to an authorized maintenance centre BELL...

Page 2: ...oduct should be installed abd operated in a professional 19 standard rack with adequate ventilation DISCLAIMER BELL products have been expressly designed for audio application with signals in audio ra...

Page 3: ...ce only Pushed again Edit button activates EDIT CH B Pushed again Edit button activates EDIT CH A AMP Status LED Blue off Stereo Mode normal Blue on Bridge Mode Yellow on DSC active Red on Protect Mod...

Page 4: ...SYSTEM UTILITY Amplifier Type Mode SYSTEM UTILITY Amplifier Type Mode NAV PROGRAM UTILITY Delete a Program PROGRAM UTILITY Delete a Program SECURITY UTILITY User Password SECURITY UTILITY User Passwor...

Page 5: ...Amp Mains Power Power ON Amp Mains Power Power ON PM1 Enter Default setting of AMP MAINS POWER is POWER ON This parameter will not be stored with command Save Program to PC and Save Program to Device...

Page 6: ...Disable Set Default Values Set Default Values Level Pot Level Pot SYSTEM UTIlity Channel Link SYSTEM UTIlity Channel Link Channel Link Link OFF Channel Link Link OFF Enter ESC quit Default setting of...

Page 7: ...Mode Display will show that Channels A and B are linked Any change of parameter for channel A will also be true for channel B In Channel Link Mode display will read IN A B instead of In A and In B EQ...

Page 8: ...r any extreme change of parameter is executed in one single step via the PC software Such abrupt changes are not possible when using the unit s encoder on the front panel Example EQ Gain is changed fr...

Page 9: ...s Any previously active parameters will be replaced by those of the last loaded program Enter ESC quit PM1 Recall a Program 12 Theater Hamburg Recall a Program 12 Theater Hamburg Enter Loading New Pro...

Page 10: ...ert Hall Enter Enter to Save 14 King Albert Hall Enter to Save 14 King Albert Hall Enter PM1 Enter to Overwrite 14 King Albert Hall Enter to Overwrite 14 King Albert Hall Saving to Memory 14 King Albe...

Page 11: ...e ID Num 01 Enter PM1 sets an individual ID number for each SMP_QX amplifier When a quantity of SMP_QX amps is working in the same system interfaced via RS485 each one must be given a different ID num...

Page 12: ...When parameter will not be shown is active and when at the same time Utility Procedures Lock Unit and Enable Password are active no parameters will be shown in the menus Edit and Utility If 2 is true...

Page 13: ...Enter Enter Enable Password Enable Password Enter Password Enter Password Enter ESC quit Enable Password Password Disable Enable Password Password Disable PM1 Enter Security UTILITY Enable Password S...

Page 14: ...nel A and channel B PM2 Noise Level Type Level 10dBu Type White Noise Level Type Level 10dBu Type White Noise Generator Utility Noise HPF Settings Noise Generator Utility Noise HPF Settings Noise HPF...

Page 15: ...hannel A Channel B NAME NAME NAV SOURCE SOURCE NAV LEVEL LEVEL NAV RMS LIMITER RMS LIMITER NAV DELAY DELAY NAV POLARITY POLARITY NAV HPF HPF NAV LPF LPF NAV EQ BYPASS EQ BYPASS NAV EQ 1 8 EQ 1 8 NOISE...

Page 16: ...lity Menu When the noise generator is active it will automatically cut any incoming audiosignal on the same channel Pink Noise to CH A aPink Noise OFF Pink Noise to CH A aPink Noise OFF Pink Noise to...

Page 17: ...e Routing InA InB has been selected the summing Output Level is 0dB not 6dB Default settings for SOURCE Signalquelle Default settings for SOURCE Signalquelle Setup STEREO CHANNEL A IN A CHANNEL B IN B...

Page 18: ...an input level of 4dBu and output level of 2dBu is to be expected The performance of the RMS limiter is best shown in the PC software Enter ESC quit PM1 Out A Low A Level aLevel 0 0dB Out A Low A Lev...

Page 19: ...Peak Limiter there will be an interference in dynamics when both limiters work on the same threshold level Such extreme settings should only be chosen to fully avoid any peaks from exceeding a certai...

Page 20: ...active using PM1 DSC Processor will boost the overall dynamics of sound DSC means extended dynamics fundametal dry subs and transparent crystal clear treble Out A Low A Polarity aPolarity Normal Out...

Page 21: ...t A Low A EQ 1 aType HiSHF 6 f 3 06kHz Default setting of EQ Type is BELL EQ The default setting of EQ Frequency is 1 00kHz In the given example EQ Type is changed to High Shelving Filter 1st order an...

Page 22: ...Cuts mains GND from PCB GND Speaker Output CHANNEL A CHANNEL B BRIDGE For Speakon Type Connectors Pin code 1 1 Impedance Selector SMP 3000QX only 2 OHM Mode Yellow LED on 4 OHM Mode Yellow LED off RS...

Page 23: ...X amp use a high quality balanced line XLR XLR mic cable In order to connect a any larger number of devices up to 32 pcs connect the RS485 Link socket of the 1 st device with the RS485 input socket of...

Page 24: ...ur PC System Hardware Device Manager Interface COM and LPT The required COM Port number will be indicated under USB Serial Port In the given example it is COM3 In order to control only 1 device the ma...

Page 25: ...ce name The background color of the individual devices is green with black script as long as the main window of the devices are closed As soon as the Main window of any device is opened by double clic...

Page 26: ...ilable when all active decive windows are closed In this case the devices in the ID list will be shown with black writing on green background This command will scan the entire network for connected de...

Page 27: ...mand will overrite the current program setting All parameters loaded will be transferred to the device and will be activated A program will include all parameters with the exception of Noise generator...

Page 28: ...ctive device window A program will include all parameters with the exception of Noise generator on off EQ bypass after loading the program EQ bypass will be reset to OFF EQ active Power Noise generato...

Page 29: ...Channel B Utilities etc This program may have been composed as the setting for a specific Hall etc A Preset will only contain the parameters of a single amp channel No utility settings Likewise the P...

Page 30: ...he active output channel to the PC A preset will include all parameters with the exception of Noise generator on off EQ bypass after loading the program EQ bypass will be reset to OFF EQ active Routin...

Page 31: ...nation devices by ticking the click boxes To copy the output name tick the box Include output name The copy process will be started by the Copy program to selected devices button While copying all act...

Page 32: ...the Master ID on green background The Device Link main window will open Master ID and device name will be shown The Copy Master to Slave click box is always activated To copy the output name tick the...

Page 33: ...Slave window Selecting the green Master button will open the Device Link Window with Active Unlink Button This window now allows the user to select or cancel any Master to Slave Link The button Link...

Page 34: ...unction of a limiter with parameters threshold and ratio In the PC software both EQ parameters BW and Q will be shown Q will not be shown in the device display Output Channel window Output Channel win...

Page 35: ...only Out InA shows the graph of the mathematical addition of Input Gain CH A the frequency response of the Output CH A CH B shows additionally the frequency response of the Output CH B respectively wh...

Page 36: ...ock some parameters of an output channel preset in order to avoid manipulation This function may only be activated deactivated by the manufacturer Locked parameters will not be displayed in the freq r...

Page 37: ...37 1 BEA SMP_QX_E IO Meter Delays Window IO Meter Delays Window Utility Window Utility Window...

Page 38: ...5kg Digital DSC Prozessor on board Durch den pro Kanal zuschalt baren digitalen DSC Prozessor erf hrt die erlebte Dynamik der SMP QX Endstufen eine geradezu dramatische Aufwertung Digital DSC steht f...

Page 39: ...de Main power on off Level Potentiometer Amp Type Mode DSC Dynamic Signal Control Channel Link Set default value Delay Units Ramp Function Software Version Program Utilities Program Recall Program Sav...

Reviews: