3.14
Start-Stop Pulse Contact
ISS
5,
SECTION
573-127-703
(A) CONTACT LEVER
To Check
Remove contact assembly from unit.
Insure that no clearance exists be
tween the contact lever and insulator.
Requirement
20
grams---Max
30
grams
to move insulator from contact
operating lever.
To Adjust
Bend lower contact spring.
UPPER CONTACT SPRING
LOWER CONTACT SPRING
(B) CONTACT GAP (START AND STOP
Requirement
Min
0.012
inch---Max
0.018
inch
(Front Views)
CONTACT OPERATING LEVER
To Adjust
Bend upper contact spring.
(C) CONTACT BRACKET
To Check
Place unit in stop position. Latch
clutch. Check clearance between
contact operating lever and transfer
lever.
Requirement
0.012
inch---Max
0.018
inch
To Adjust
Loosen mounting bracket screws.
Position contact assembly to meet
requirement. Retighten mounting
bracket screws. Replace contact
assembly in unit.
Page
47
4--·-
-