2.14
Tight-Tape Mechanism
START-STOP SWITCH BRACKET (For Units Equipped with
Tape Lid Sensing Lever)
To Check
Place intermediate tight-tape arm to
center of its adjusting range with the
contact arm.
(1)
Requirement
Tight-tape start-stop contacts to:
(a) Remain closed when tight
tape bail is raised
0.045
inch
(b) Open as bail is raised to
0.075
inch.
To Adjust
(a) Loosen tight-tape intermediate
arm clampscrew. Position pry
point midway in contact operating
arm adjusting slot. Retighten
clampscrew.
(b) Loosen switch bracket screws
friction tight. Position contact
pile-up to meet requirement.
(2)
Requirement
Contact arm to fully engage insulated
part of switch swinger.
To Adjust
Loosen contact pile-up mounting
screws. Position contact pile-up
mounting bracket. Retighten mount
ing screws.
TIGHT-TAPE BAIL
TIGHT-TAPE
INTERMEDIATE ARM
CLAMP-
SCREW
P RY
CONTACT
ARM
0
0
PRY
POINT
ISS
5,
SECTION
573-127-703
CONTAC T PILE-UP
MOUNTING SCREWS
0
(Top View)
SWITCH BRACKET
MOUNTING SCREWS
Page