6
A Triple Duty Valve, such as the one manufactured by Bell &
Gossett, installed in the discharge line will serve as a check
valve to protect the pump from water hammer, as an isolation
valve for servicing and for throttling.
NOTES:
1. The pipeline should have isolation valves around the pump
and have a drain valve in the suction pipe.
2. When installing the suction and discharge connections to a
threaded pump housing the use of teflon tape sealer or a
high quality thread sealant is recommended.
LUBRICATION
While pump is running regrease pump bearing with NLGI
Grade #2 lithium base petroleum grease after every 2500
hours of operation or every 6 months whichever occurs first.
Lubricate motor per motor manufacturer’s instructions.
GENERAL INSTRUCTIONS
1. Keep this pump and motor properly lubricated.
2. When there is a danger of freezing, drain the pump.
3. Inspect pump regularly for leaky seals or gaskets and loose
or damaged components. Replace or repair as required.
PUMP INSULATION
When insulating a Series 1510 pump, ensure that the bearing
assembly grease fittings remain accessible and visible. The
vent slots on the sides and bottom of the bearing assembly
should remain uncovered and completely open.
FIGURE 8
HEX GUARD EXPLODED VIEW FOR TYPICAL INSTALLATION
INNER GUARD
ATTACH SUPPORT BRACKET
TO PUMP SIDE OF SUPPORT
THIS OPTION USED IN PLACE OF SPACER WHERE
OVERALL LENGTH OF GUARD EXCEEDS 12 INCHES
OR GUARD WIDTH IS OVER 10 INCHES ACROSS
THE FLATS.
OUTER GUARD
NUT
LOCKWASHER
LOCATE SUPPORT ARM
BETWEEN OUTER GUARD ENDS.
ALIGN THE ARM WITH HOLES IN
THE OUTER GUARD AND HOLES IN
THE SADDLE BRACKET.
SUPPORT BRACKET
CAPSCREW
FLAT WASHER
THE SUPPORT BRACKET
ATTACHES INSIDE HERE
INLINE WITH BOLT
MOTOR SADDLE BRACKET
ATTACH TO MOTOR SADDLE
SPACER WASHER