background image

8

FIGURE 11

1510-S

FIGURE 12

1510-D

MOTOR END

O-RING

COVERPLATE

MOTOR END

O-RING

O-RING

FOR 1

5

/

8

" AND

2

3

/

8

" SEAL 1

1

/

4

"

SEAL LOCKING COLLAR

SEAL CAP BOLTS

SEAL CAP

O-RING

FOR 1

1

/

4

" SEAL

1

13

/

32

"

SERVICE INSTRUCTIONS

1. Close valves on suction and discharge sides of pump. (If

no valves have been installed, it will be necessary to drain
the system.)

2. Remove the Hex Coupler Guard as follows (see figure 8):

a. Remove the two cap screws that hold the outer (motor

side) coupler guard to the support bracket(s).

b. Spread the outer guard and pull it off the inner guard.

NOTE:

Do not spread the inner and outer guards more

than necessary for guard removal. Over spreading the
guards may alter their fit and appearance.

c. Remove the cap screw that holds the inner guard to the

support bracket.

d. Spread the inner guard and pull it over the coupler.

3. Loosen set screws in both coupler halves and slide each

half back as far as possible on its shaft. Remove coupler
sleeve. Where a full diameter impeller is used, it may be
necessary to remove the pump side coupler half and to
slide the motor back on its base in order to gain sufficient
clearance to remove the pump assembly from the volute.

4. Remove support foot capscrews. Loosen volute cap-

screws, do not remove them. Use capscrews in the jack
screw holes (Not on 8G). Loosen the pump assembly from
the volute.

Remove seal flushing tube, if used.

Remove the volute capscrews and remove the pump
assembly from the volute.

Continue to the section which pertains to your pump type.

1510 and 1510-F
With Standard Mechanical Seal – Figure 9

5. Remove the impeller capscrew, lock washer and washer.

Remove the impeller.

6. Remove the rotating portion of the seal, use a screwdriver

to loosen the rubber ring.

7. Remove the seal insert along with the insert gasket and

retainer (if used).

8. Thoroughly clean the shaft sleeve and the coverplate seal

cavity. Inspect for surface damage like pitting, corrosion,
nicks or scratches. Replace if necessary.

WARNING: UNEXPECTED STARTUP HAZARD

Disconnect and lock out power before servicing.

Failure to follow these instructions could result in serious per-
sonal injury or death, or property damage.

WARNING: EXCESSIVE PRESSURE HAZARD

Make certain internal pressure of the pump is relieved

before continuing. Failure to follow these instructions could re-
sult in serious personal injury or death, or property damage.

CAUTION: EXTREME TEMPERATURE HAZARD

Allow pump temperature to reach acceptable levels

before proceeding. Open drain valve, do not proceed until
liquid stops coming out of drain valve. If liquid does not
stop flowing from drain valve, isolation valves are not seal-
ing and should be repaired before proceeding. After liquid
stops flowing from the drain valve, leave valve open and
continue. Remove the drain plug located on the bottom of
the pump housing. Do not reinstall plug or close drain valve
until re-assembly is completed. Failure to follow these
instructions could result in property damage and/or moder-
ate personal injury.

Summary of Contents for 1510/Universal Series

Page 1: ...LER PLEASE LEAVE THIS MANUAL FOR THE OWNER S USE Series 1510 and 1510 Universal Centrifugal Pumps Installation Operation and Service Instructions INSTRUCTION MANUAL P81673 REVISION F Bell Gossett Bell Gossett ...

Page 2: ...oupler and regreasable bearings These features make installation operation and service easy to perform PUMP APPLICATION The standard Series 1510 centrifugal pump s bronze fitted construction make it ideal for service with following liquids unheated domestic and fresh water boiler feed water conden sate hydronic cooling or heating pressure boosting general pumping and benign liquids For other appli...

Page 3: ...NG Electrical Overload Hazard Three phase motors must have properly sized heaters to provide overload and undervoltage protection Single phase motors have built in overload protectors Failure to follow these instructions could result in serious personal injury or death or property damage WARNING Extreme Temperature Hazard If pump motor or piping are operating at extremely high or low temperatures ...

Page 4: ...bolt to provide a means of leveling the base See Figure 6B IT IS VERY IMPORTANT THAT THE PUMP BASE BE SET LEVEL TO AVOID ANY MECHANICAL DIFFICULTIES WITH THE MOTOR OR PUMP THIS PUMP WAS PROPERLY ALIGNED IF FURNISHED WITH A MOTOR AT THE FACTORY HOWEVER SINCE ALL PUMP BASES ARE FLEXIBLE THEY MAY SPRING AND TWIST DURING SHIPMENT DON T PIPE THE PUMP UNTIL IT IS REALIGNED AFTER PIPING IS COMPLETED AND ...

Page 5: ...tings then orange Hytrel sleeves they should not be interchanged Standard Sleeve Type Coupler with Black Rubber Sleeve Before aligning the coupler make sure there is at least 1 8 end clearance between the sleeve and the two coupler halves 1 Check angular misalignment using a micrometer or caliper Measure from the outside face of one flange to the outside face of the opposite flange at four points ...

Page 6: ... properly lubricated 2 When there is a danger of freezing drain the pump 3 Inspect pump regularly for leaky seals or gaskets and loose or damaged components Replace or repair as required PUMP INSULATION When insulating a Series 1510 pump ensure that the bearing assembly grease fittings remain accessible and visible The vent slots on the sides and bottom of the bearing assembly should remain uncove...

Page 7: ...ELLER LOCK WASHER IMPELLER WASHER DRAIN PLUG IMPELLER CAPSCREW STANDARD MECHANICAL SEAL CONSTRUCTION FIGURE 10 IMPELLER VOLUTE VOLUTE GASKET COVER PLATE COVERPLATE CAPSCREWS FLUSHING TUBE LANTERN RING PACKING PACKING GLAND BEARING FRAME SHAFT SLINGER SHAFT SLEEVE BRACKET IMPELLER KEY IMPELLER W ASHER VOLUTE CAPSCREWS IMPELLER LOCK WASHER IMPELLER CAPSCREW DRAIN PLUG STUFFING BOX CONSTRUCTION ...

Page 8: ...apscrews and remove the pump assembly from the volute Continue to the section which pertains to your pump type 1510 and 1510 F With Standard Mechanical Seal Figure 9 5 Remove the impeller capscrew lock washer and washer Remove the impeller 6 Remove the rotating portion of the seal use a screwdriver to loosen the rubber ring 7 Remove the seal insert along with the insert gasket and retainer if used...

Page 9: ...onto shaft sleeve and lock in place For 11 4 I D seals the collar should be 113 32 from the impeller end of the shaft sleeve For 15 8 and 23 8 I D seals the distance should be 11 4 See Figure 11 9 Assemble coverplate to bracket tighten capscrews per torque chart See Table 1 Assemble seal cap to cover plate tighten hex nuts on seal cap bolts per torque chart See Table 1 10 Go to Step 11 of 1510 Sta...

Page 10: ...s loose Re tighten with fingers until gland is just snug against the first packing ring Initially water may run freely from packing This is normal and should be allowed to continue for a period of time before further tightening of the gland Tighten gland nuts slowly and uniformly one flat at a time An adequate leakage rate is not one single value for all pumps and installations but is the amount r...

Page 11: ... 1 4 5 16 3 8 7 16 1 2 5 8 SAE Grade 1 2 3 6 10 16 24 46 Stainless Steel SAE Grade 5 8 17 30 50 76 48 CAPSCREW TORQUE FOOT POUND Bell Gossett COPYRIGHT 1970 1999 BY ITT INDUSTRIES INC DIN ISO 9001 TUV CERT ISO 9001 Certified PRINTED IN U S A 6 99 USA Bell Gossett 8200 N Austin Avenue Morton Grove IL 60053 Phone 847 966 3700 Facsimile 847 966 9052 http www bellgossett com INTL Bell Gossett Export D...