background image

5

4

5

Features and Functions

Front-Panel 
Label

Visual 
Indicator

Audible Alarm

Description

AC Power

AC Power LED 
lights

None

The Unit is operating normally on AC power.

Battery Power

Battery Power 
LED lights

Tone every 
10 seconds

The Unit is operating on battery power. 
The alarm will stop when main AC power 
is returned.

Low Battery

Low Battery LED 
fl ashes

Tone every 
1 second

The battery energy is running low. This alarm 
will continue until the Unit performs a forced 
shutdown when the battery is depleted.

Fault

Fault LED lights

Continuous tone

A fault has occurred. Disconnect all 
equipment from the Unit prior to checking.

Overload

Overload LED 
fl ashes

Tone every 
1 second

The Unit is overloaded. Remove connected 
equipment until fault mode is cleared.

Replace Battery

Replace Battery 
LED lights

None

The battery has reached the end of its useful 
life. The user must replace the battery as 
soon as possible to ensure proper operation 
of the Unit.

LED Indicators and Audible Alarms  

The Unit will alarm to indicate certain events.

Low Battery           press and hold            Overload

AC Power     Battery Power                                                Fault       Replace Battery

NOTE: The audible alarm will not sound after the alarm is muted.

Flashlight 

The Unit contains a fully functional, detachable 
LED flashlight. The flashlight will automatically 
illuminate when the power goes out. This safety 
function provides an easy way for you to find the 
flashlight while illuminating the area surrounding 
the Unit. The LED flashlight may be removed from 
the Unit to use as a handheld, portable flashlight.
To remove the LED flashlight from the Unit’s 
recharging dock, pull the top of the LED flashlight 
out and downward until it disengages. When 
not in use, return the LED flashlight to the Unit’s 
recharging dock. The LED flashlight will only 
fit one way in the recharging dock: with the 
flashlight lens pointing toward the top of the Unit 
and the LED flashlight button toward the outside. 
The LED flashlight will only recharge if properly 
docked on the Unit.

Flashlight Recharging and Battery Replacement 
CAUTION:

•  The detachable LED flashlight contains 3 

NiMH 700mAh AAA batteries. When replacing 
batteries, replace with the same number 

and type of batteries. Do not attempt to use 
alkaline or other non-NiMH battery types 
for replacement.

•  Risk of energy hazard. Before replacing 

batteries, remove conductive jewelry such as 
chains, wristwatches, and rings. 

High energy 

through conductive materials could cause 
severe burns.

• Do not short-circuit the batteries.
•  Carefully install the batteries in the LED 

flashlight housing, ensuring proper polarity. 
Reverse polarity installation may cause 
damage. The battery installation polarity is 
labeled on the LED flashlight housing.

•  Do not heat or incinerate the battery. The 

battery may explode.

•  Only use the UPS Unit to recharge the 

batteries. Charging under other conditions 
can cause the battery to leak, overheat, burst, 
and/or catch fire.

• Properly dispose or recycle used batteries.

Summary of Contents for BU305500-USB

Page 1: ...Lighthouse Battery Backup BU305500 USB User Manual...

Page 2: ...ated services placing your hardware software and data at risk This innovative new power accessory includes a detachable rechargeable flashlight that illuminates immediately in the event of a power out...

Page 3: ...le LED Flashlight 1 Installation CD containing Belkin Automatic Shutdown Software 1 USB Cable 1 Phone Line Cable 3 AAA NiMH Batteries Safety Information CAUTION Risk of electrical shock hazardous live...

Page 4: ...o organize and manage the power cables from your connected equipment Route all power cables through the loop for a clean and organized workspace 2 The On Off button has four functions Fig 2 a Turns on...

Page 5: ...o find the flashlight while illuminating the area surrounding the Unit The LED flashlight may be removed from the Unit to use as a handheld portable flashlight To remove the LED flashlight from the Un...

Page 6: ...l and Audible Input Breaker 10A 125VAC UL cUL Surge Energy 700 Joules Suppression Total Performance Rated With 10 1000 s Pulse Efficiency AC Mode 90 Input Voltage 120VAC Switching Load 300W Battery Mo...

Page 7: ...make sure all of the loads are switched on Caution Never connect a laser printer or scanner to the backup outlets along with other computer equipment A laser printer or scanner draws significantly mo...

Page 8: ...line into the surge protected outlets on the back of the Unit The RJ11 modular outlet accepts standard single line telephone connections The connection will require another length of telephone cable i...

Page 9: ...ulldog Plus Monitor To access this screen please click the Belkin InstallShield Wizard found in the lower right hand corner on your taskbar Once the Bulldog Plus Online screen appears choose Help The...

Page 10: ...t and the Unit charging dock using a dry lint free cotton cloth Do not use any liquid to clean these surfaces 3 If the LED flashlight does not appear to recharge after cleaning the contacts replace th...

Page 11: ...this Agreement You agree that upon such termination you will immediately destroy all programs and documentation including all copies made or obtained by you SOFTWARE PROGRAM DOCUMENTATION AND ANY RELA...

Page 12: ...ead this Agreement understand it and agree that this Agreement is the complete and exclusive statement of agreement between yourself and Belkin and supersedes any prior agreements oral or written and...

Reviews: