8
9
2. In Control Panel, locate and click on the
“Add/Remove Programs” icon. The
“Add/Remove Programs” window will appear.
3. Locate and select the Belkin Bulldog Plus
Software. Click the “Change/Remove” button
on the right. InstallShield Wizard will appear.
4. Choose “Remove” and click “Next”.
5. “Program Files” and “Audio Files” will be
checked. If they are not, please check them.
Click “Next”. The uninstall procedure
will begin.
6. Click “Finish” when complete.
Belkin Automatic Shutdown Software Installation
Troubleshooting
PROBLEM
POSSIBLE CAUSE
SOLUTION
Flashlight does not
turn on or operates
abnormally
Flashlight batteries not
fully charged
Return the LED flashlight to the Unit
charging dock and charge for at least
8 hours.
Flashlight does not
charge—Unit charging
dock not functioning
1. Make sure the UPS Unit is plugged in
and turned on.
2. Clean off the 2 metal contacts on the
flashlight and the Unit charging dock
using a dry, lint-free cotton cloth. Do not
use any liquid to clean these surfaces.
3. If the LED flashlight does not appear
to recharge after cleaning the contacts,
replace the rechargeable NiMH batteries
using identical replacement batteries.
Unit not on, LED not lit
“On/Off” button not
pushed or pushed less
than 2 seconds
Press the “On/Off” button for more than
2 seconds
Battery voltage is too
low
Recharge the Unit at least 8 hours
UPS fault
Contact service personnel
(1-800-2 BELKIN)
Unit always on battery
mode
Power cord loose
Re-plug the power cord
AC breaker is burned
out or tripped
Replace or reset the breaker
AC utility voltage is
too high or too low, or
there is a blackout
Normal condition
Backup time too short
Battery not fully
charged
Recharge the Unit at least 8 hours
The Unit is on overload
Remove some unnecessary loads
Charger fault or other
reason
Replace battery;
contact www.belkin.com
The Unit continuously
beeps
Overload
Disconnect non-critical devices
Red LED lit
Battery failure
Replace battery;
contact www.belkin.com