background image

13

KMV-3901/3911

Quick Start Guide

Finding the System IP Address and Application Version

To find the system IP address and application version

1 Press the Select button on the front edge of the KMV-3901/3911 card.

The Status LED on the selected card flashes orange, and the associated control menu 
appears on the display of the Densité frame’s local control panel.

2 On the local control panel, press the [–] button.

The version of the Kaleido-X Software that is running on the card (e.g. “5.00-build.21”) 
appears on the display.

3 On the local control panel, press the [–] button repeatedly until NETWORK SETTINGS 

appears on the display, and then press the SEL button:

IP ADDRESS EDIT appears on the control panel’s display.

4 Press the SEL button again.

The current IP address appears on the display.

5 Press the Select button 

on the front edge of the KMV-3901/3911 card

 to exit the control 

menu.

Using the Kaleido-RCP2 with Default Settings

Select button

Status LED

Boot LED,
Power LED,
CPU Status LED (other side of board)

SDI LEDs

USB connector (other side of board)

Note:

The Kaleido-RCP2 unit is optional and is not included in the standard 

KMV-3901/3911 package.

Summary of Contents for Miranda KMV-3901

Page 1: ...Quick Start Guide M866 9905 109 12 January 2014...

Page 2: ...on and license to owners of Kaleido multiviewers to use their product manuals for their own internal business use Manuals for Miranda products may not be reproduced or transmitted in any form or by an...

Page 3: ...Surge transient immunity EN 61000 4 6 Conducted disturbances immunity EN 61000 4 8 Power frequency magnetic field immunity EN 61000 4 11 Voltage dips short interruptions and voltage variations immunit...

Page 4: ......

Page 5: ...e KMV 3901 3911 cards can be configured into a single or dual output system supporting up to 24 inputs At the heart of every multiviewer system is the Kaleido X software which includes two client appl...

Page 6: ...3911 or KMV 3901 card front and rear modules One or two 35 cm 14 inch DIN to BNC cable adapters for KMV 3911 models with HD SDI monitoring output option only The KMV 3901 3911 Quick Start Guide this...

Page 7: ...s On all Miranda multiviewers the network adapters are set to auto negotiate By default the connection speed and duplex mode will be set automatically based on the corresponding port settings on the s...

Page 8: ...roller Card with firmware version 2 0 4 or later A controller with an earlier version of the firmware cannot provide a time reference to the multiviewer card Make sure the controller s internal clock...

Page 9: ...eo inputs are green Notes The Kaleido RCP2 is an optional device and may not have been shipped with your KMV 3901 3911 system For information on this and other options for your multiviewer system plea...

Page 10: ...red with the same refresh rate If your frame is referenced then the heads refresh rate must also match the reference signal s refresh rate Note You can navigate the control menu by using the four butt...

Page 11: ...button HEAD 2 appears on the LCD display and you can repeat step 4 to step 8 above to verify or configure the resolution of the display that is connected to the multiviewer s output head 2 i e through...

Page 12: ...rds it will not be necessary to switch off the Densit frame s power when installing or removing cards IMPORTANT If you need to install or momentarily remove a Densit card s rear module make sure to fi...

Page 13: ...on if needed 1 On the Densit frame s local control panel press the CONTROLLER button 2 Press the button repeatedly until RESTORE POINTS appears on the display and then press the SEL button 3 Press the...

Page 14: ...e the current value at the current input position Press SEL to move one position to the right Note You can navigate the control menu by using the four buttons located beneath the display Press the and...

Page 15: ...tely five minutes during which time the Status LED is blinking orange Once the startup has completed the Status LED should be red steady because the card is not connected to the network yet 11 Connect...

Page 16: ...the SEL button 16 Press the button repeatedly until SAVE A CARD appears on the display and then press the SEL button 17 Press the button repeatedly until CARD N where N matches the slot number for th...

Page 17: ...card e g 5 00 build 21 appears on the display 3 On the local control panel press the button repeatedly until NETWORK SETTINGS appears on the display and then press the SEL button IP ADDRESS EDIT appea...

Page 18: ...in the list or the 8 key to move down the list until Room1 is displayed 5 Press ENTER and then press ESC to exit the configuration menu 6 Press the LOGIN button The following message appears on the LC...

Page 19: ...lternatively connect the mouse directly to the USB port at the front of the KMV 3901 3911 card 2 Right click anywhere on the monitor wall point to Monitor wall if you clicked a monitor and then click...

Page 20: ...In Network Connections right click Local Area Connection and then click Properties If the system prompts you for an administrator password or confirmation type the password or provide confirmation Th...

Page 21: ...and then click Open on the shortcut menu 2 In Network Connections right click Local Area Connection and then click Properties on the shortcut menu 3 In Local Area connection Properties select Interne...

Page 22: ...et as the multiviewer open a Web browser window and type the multiviewer s IP address in the address bar The Kaleido X home page appears 2 Click the XEdit button The browser prompts you to save an exe...

Page 23: ...indow appears showing the download and installation progress At the end of the installation process launcher icons are added to your desktop and to the Start menu under All Programs Once the installat...

Page 24: ...r automatically in which case a message will appear to confirm the font update and instruct you to restart the application Click OK to continue and then open XEdit again by using the launcher icon on...

Page 25: ...ped with your system and from Miranda s support portal Note Once it has been installed from the multiviewer XEdit remains on your PC or laptop and can be launched from the icon that was added to your...

Page 26: ......

Page 27: ...514 335 1614 E mail support miranda com Asia Office hours 9 00 a m 5 00 p m GMT 8 Telephone 852 2539 6987 Fax 852 2539 0804 E mail asiatech miranda com Europe Middle East Africa UK Office hours 9 00...

Reviews: