Installation BAT-R
Release 17 12/2020
69
10.8
Network range
Note:
The line lengths specified for the transceivers apply for the respective
fiber data (fiber attenuation and Bandwidth Length Product (BLP)/
Dispersion).
EN 61000-4-4
Fast transients (burst), test level 4
DC power line
±4 kV
AC Power Line
±4 kV
Data line
±4 kV
EN 61000-4-5
Voltage surges
DC power line
±2 kV line/ground; ±1 kV line/line
AC Power Line
±4 kV line/ground; ±2 kV line/line
Data line, shielded
±4 kV line/ground
Data line, unshielded
±2 kV line/ground
Data line, unshielded
±1 kV line/line
EN 61000-4-6
Conducted interference voltages, test level 3
150 kHz ... 80 MHz
10 V
EN 61000-4-9
Pulse magnetic fields
300 A/m
EMC interference
emission
EN 55032
Class B
FCC 47 CFR Part 15
Class A
Immunity
Vibration
IEC 60068-2-6 Test FC test level according to IEC 61131-2
Shock
IEC 60068-2-27 Test Ea test level in accordance with IEC 61131-2,
EN 50155
Product
code
M-SFP-...
Wave
length
Fiber
System
attenuatio
n
Example
for F/O
cable
length
a
Fiber
attenuatio
n
BLP
b
/
Dispersion
-SX/LC... MM 850 nm
50/125 µm
0 dB ...
7.5 dB
0 mi ...
0.34 mi
(0 km ...
0.55 km)
3.0 dB/km
400 MHz×km
-SX/LC... MM 850 nm
62.5/125 µm 0 dB ...
7.5 dB
0 mi ...
0.17 mi
(0 km ...
0.275 km)
3.2 dB/km
200 MHz×km
Table 20: F/O port 1000BASE-FX (SFP fiber optic Gigabit Ethernet Transceiver)
EMC interference
immunity