Lightning protection and surge protection
Applies exclusively to antennas installed outdoors:
The lightning protection measures must be carried out by a lightning
protection professional in accordance with valid standards (such as
IEC 62305 / DIN EN 62305 (VDE 0185-305)), and in accordance with
the lightning protection procedures recognized and proven for the
application and the environment.
Refer to the information in the “WLAN Outdoor Guide” on “Lightning
protection and surge protection”.
The manual is available for download on the Internet:
www.doc.hirschmann.com
Ensure that the lightning protection professional installs lightning
protection devices (for example lightning conductors) to protect
antennas installed outdoors.
Ensure that the lightning protection professional takes appropriate
lightning protection measures that mitigate the effects of lightning
strikes.
Requirements for connecting electrical wires
Before connecting the electrical wires,
always
verify that the
requirements listed are complied with.
The following requirements apply without restrictions:
The electrical wires are voltage-free.
The cables used are permitted for the temperature range of the application case.
Relevant for North America:
The power supply cables are suitable for ambient air temperatures of at least +167 °F
(+75 °C). The wires of the power supply cables are made of copper.
Table 1:
Requirements for connecting electrical wires