37
EESX20 and EESX30
Release 1.5 04/2020
4 Heat sink
Case Temperature on the EESX-Board
Note:
The Case temperature on the EESX module should not be exceeded!
Case temperature for EESX20:
91°C
Case temperature for EESX30:
85°C
4.1 Permissible operating temperature
The maximum permissible operating temperature of the EESX module is +91 °C for EESX20 and +85°C
for EESX30 at the measuring point of the Case Temperature. Operate the device only up to this
maximum temperature.
The measuring point for the Case temperature of the EESX module is on the bottom side. See the
following picture where the Case Temperature has to be measured on ESSX module.
Figure 4-1: Measure Case temperature on the chip near the long connector
In case of exceeding the case temperature during operation an additional cooling will be necessary. The
module will be offered also with a mounted cooling plate where an additional heat sink can be mounted
on the top.
See details in chapter
“Mechanics”.