12
EESX20 and EESX30
Release 1.5 04/2020
Status
Description
POWER
Off
Green
EESX-Evaluation-Board is unpowered.
EESX-Evaluation-Board is powered.
RELAY
Off
Green
Signal “Relay_Control” is low, System is not
ready.
Si
gnal “Relay_Control” is high, System is ready.
SWBOOT2
Off
Green
Software is not loaded.
Software is loaded.
READY
Off
Light green
Software is not loaded, System is not ready.
Software is loaded, System is ready.
ALARM
Off
RED
System (software) is running.
System indicates abnormal operation status.
SWBOOT1
Off
Green
Software is not loading.
Software is loading.
GE-
Port[1..2]
Off
Green
Off
Yellow blinking
No link (no physical connection).
Link is up (physical connection available).
No data traffic.
Data traffic.
FE-
Port[1..8]
Off
Green
Off
Yellow blinking
No link.
Link is up.
No data traffic.
Data traffic.
Table 1-2: LED status indication
1.8 Measuring Point Connectors
The 12-pin, dual-row connector on the EESX-Evaluation-Board give access to several EESX spare
signals on connector CO402 which are reserved for future use. (See (10) in Figure 1-1.)
The signals are LVTTL level.
Figure 1-9: EESX-Evaluation-Board schematic (part Measuring points)