12
Installation
Testing
that panel should be loaded and the buttons appropriate for that configuration should
light in the colors appropriate for that configuration.
If you continue to see “No Server,” “Acquiring IP Address,” or “Locating Network” on
button 2, you might have a problem. Reboot everything and try again.
The NV9641, by default, acquires its IP address through DHCP on the panel/router
network of the system controller. You can use the Panel IP Configuration Utility to
force the panel to have a static IP address.
If (in setup mode) you do not see your designated panel ID on the first button, you have
either not initialized the panel or no configuration has been created for your panel in
NV9000-SE Utilities.
3 Is the system controller actually running? It can sometimes be difficult to tell.
4 Is NV9000-SE Utilities installed and operating? If so, can you upload a configuration to
the specified panel?
5 Does the configuration actually work? Can the operator perform takes and perform
other operations?
The design of an NV9641 “operator interface” is non-trivial. You might want to consider how
well your operator interface works in addition to the basic question of whether it works.