background image

31

LUMO

User Manual

-or-

Click the Select All box at the top to activate the feature for all slots in the frame. 

Click 

Save to controller

 at the bottom to 

copy all restorable data from the cards in 
the selected slots into the memory on 
board the LUMO-CPU-ETH controller.

Click 

Load to cards

 to load the cards in the 

selected slots with data from the 
controller’s memory. Note that a data 
restore will only work if the card in the slot 
is the same type as the card that was there 
when the data was saved.

For automatic restore and save:

Click the 

Restore Point

 button and view the 

Config

 tab.

Restore:

 The LUMO-CPU-ETH card can 

be set up to automatically update a card 
when it is inserted in a slot previously 
occupied by a card of the same type 
whose data was saved. Thus, a new card 
can be configured automatically to 
replace the card that was removed, 
saving a lot of time when cards are 
swapped.

Click the 

Default Action 

box to enable 

the auto restore function for all the cards 
in the frame.

Save:

 The LUMO-CPU-ETH card can be 

configured to automatically back up the 
data on the cards in its slots according to 
a set schedule.

Click the 

Auto Save

 box to enable the 

automatic save function.

Summary of Contents for Grass Valley LUMO

Page 1: ...User Manual M974 9900 104 2016 02 18 LUMO HIGH DENSITY FIBER CONVERTERS ...

Page 2: ...LUMOs to use their product manuals for their own internal business use Manuals for Grass Valley products may not be reproduced or transmitted in any form or by any means electronic or mechanical including photocopying and recording for any purpose unless specifically authorized in writing by Grass Valley A Grass Valley manual may have been revised to reflect changes made to the product during its ...

Page 3: ...king any other equipment connections Identifies an external protective grounding terminal which may be connected to earth ground as a supplement to an internal grounding terminal Indicates that static sensitive components are present which may be damaged by electrostatic discharge Use anti static procedures equipment and surfaces during servicing Indicates that the equipment has more than one powe...

Page 4: ...uid or aerosol cleaners use only a damp cloth Dangerous voltages may exist at several points in this equipment To avoid injury do not touch exposed connections and components while power is on High leakage current may be present Earth connection of product is essential before connecting power Prior to servicing remove jewelry such as rings watches and other metallic objects To avoid fire hazard us...

Page 5: ...trostatic Discharge ESD Protection Electrostatic discharge occurs when electronic components are improperly handled and can result in intermittent failure or complete damage adversely affecting an electrical circuit When you remove and replace any card from a frame always follow ESD prevention procedures Ensure that the frame is electrically connected to earth ground through the power cord or any ...

Page 6: ...s le texte doit être remplacé par un fusible du même calibre Identifie une borne de mise à la terre de protection Il faut relier cette borne à la terre avant d effectuer toute autre connexion à l équipement Identifie une borne de mise à la terre externe qui peut être connectée en tant que borne de mise à la terre supplémentaire Signale la présence de composants sensibles à l électricité statique e...

Page 7: ...es connecteurs Coupez l alimentation avant de nettoyer l équipement Ne pas utiliser de nettoyants liquides ou en aérosol Utilisez uniquement un chiffon humide Des tensions dangereuses peuvent exister en plusieurs points dans cet équipement Pour éviter toute blessure ne touchez pas aux connexions ou aux composants exposés lorsque l appareil est sous tension Avant de procéder à toute opération d ent...

Page 8: ...arations autres que celles qui sont décrites dans le présent manuel sauf si vous êtes qualifié pour le faire Confiez les réparations à un technicien qualifié La maintenance doit se réaliser dans un milieu libre d électricité statique L appareil peut comporter plus d un cordon d alimentation Afin de prévenir les chocs électriques débrancher tous les cordons d alimentation avant toute opération d en...

Page 9: ... fabricant Mettez les piles usagées au rebut conformément aux directives du fabricant Avant de vous défaire de l équipement assurez vous d avoir lu l appendice Disposal and Recycling Information Recycling Visit www grassvalley com for recycling information Certification and Compliance Safety Compliance This equipment complies with the requirements of CSA UL IEC EN 60950 1 2nd Ed AM1 Safety of info...

Page 10: ...communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense This equipment has been tested and found to comply with the requirements of the EMC directive 2004 108 EC EN 55022 Class A Radiated and conducted emissions EN 61000 3 2 Limits for harmonic current emissions E...

Page 11: ... hazardous substance contained in all of the homogeneous materials for this part is below the limit requirement in SJ T11363 2006 X 表示该有毒有害物质至少在该部件的某一均质材料中的含量超出 SJ T 11363 2006 规定的限量要求 X Indicates that this toxic or hazardous substance contained in at least one of the homogeneous materials for this part is above the limit requirement in SJ T11363 2006 技术条款解释 此声明所依据之数据由 Grass Valley 环境管理部门向我们的部件供应商...

Page 12: ......

Page 13: ...O CPU ETH Controller Card 19 Overview 19 Control Interfaces 20 5 FIO 911 O E and E O Converters 37 FIO 911 3G HD SD Optical to from Electrical Converters 37 FIO 911 4R LC 38 FIO 911 4T S13 LC 40 FIO 911 4TH CwwCxxCyyCzz LC 41 iControl Interface 43 Specifications 50 6 SFP Modules 53 Introduction 53 Installing an SFP module 54 Connecting the fiber optic cables 54 Removing the fiber optic cables 55 R...

Page 14: ...xiv ...

Page 15: ...pable cards and a redundant PSU as well as remote system health monitoring and alarming for all key compo nents including optical signal strength Key Features and Benefits High density 1RU frame with 36 SFP based fiber converters Supports 2 x 18 CWDM wavelengths Modular hot swappable SFPs and cards for efficient serviceability Mechanical design with fiber connectivity on one side and coax on the o...

Page 16: ...l transmitter 1310 nm LC PC connectors FIO 911 4R LC Quad 3Gbps HD SD optical receiver LC PC connectors FIO 911 4TH CwwCxxCyyCzz LC High power Quad 3Gbps HD SD optical CWDM Tx LC PC connector CwwCxx and CyyCzz show the wavelengths of the CWDM transmitters used in this card These cards can be used in any combination to occupy the nine available slots in the LUMO frame ...

Page 17: ...gned to provide maximum configuration flexibility in a high density and low cost 1 RU chassis The basic config uration includes one power supply unit and a chassis status card for basic system monitoring Up to 9 FIO 911 series cards can be installed within a single frame The LUMO frame offers full flexibility and integration of a variety of functions and signal types on BNC DIN or fiber SFP All co...

Page 18: ...face plate which allows the status LEDs on the installed cards to be seen and also allows the card to be secured in the chassis by a screw The opening near the center of the panel is for the status or controller card status LED The frame is provided with a fiber support that extends beyond the front of the frame to physi cally support the fiber cables and protect the fiber connectors from stress r...

Page 19: ...items have been shipped with your LUMO frame LUMO BNC or LUMO DIN frame including 1 Power Supply unit AC in and 1 Status card If the optional LUMO CPU ETH controller has been ordered the Status card is not included Rack mounting brackets 1 pair with 8 mounting screws An AC power cord Power cord retaining clips 2 LUMO series cards per order with associated lexans Fiber Support with 8 mounting screw...

Page 20: ...and the fiber support onto the LUMO frame The rack mounting brackets may be installed alone See section A or in combination with the fiber support If the rack mounting brackets are installed with the fiber support the fiber support must be installed first See section B A Installing the rack mounting brackets alone Position a bracket at each side of the LUMO frame and install them using the four pr...

Page 21: ...ckets first and then re install them after the fiber support has been installed as described in Section C Position the fiber support against the LUMO frame as shown in the figure and attach it to the frame with the eight provided screws Note that the fiber support configuration varies depending on the LUMO model For the standard LUMO xxx model For the LUMO xxx MPO model ...

Page 22: ... standard rack mounting screws through the four holes in the corners of the rack mount brackets Installing Cards in the LUMO Frame Each card includes an integrated front panel incorporating the fiber optic connectors All cards can be installed with the frame power on The card has a connector which plugs into a backplane for distribution of power connection to the controller card and connections to...

Page 23: ...lip down into a horizontal position Several pairs of holes are provided to accommodate different sizes of plugs Use the holes that position the clip closest to the body of the plug Once the clip is in place insert the power cord into the socket and press the cord into the grip ping loop of the clip Ventilation Ventilation for the frame is provided by a fan mounted in the center of the rear panel T...

Page 24: ...or must be kept closed while the frame is in use to ensure proper ventilation Changing the Power Supply The LUMO frame supports dual redundant hot swappable power supplies The basic configura tion includes a single supply plus an empty slot for the optional redundant power supply Installing a second power supply module and applying power to it automatically engages the redundant supply mode Each p...

Page 25: ...released from the rear connector then slide the card out of the frame 3 Slide the new card into the controller slot and push gently on the card edge to engage the rear connectors 4 Pull the door mounting brackets back out of the frame and re install the door onto the brackets 5 Be sure to close the door before operating the LUMO system to ensure proper ventilation Replacing the Frame Ventilation F...

Page 26: ...o screws that were retained when the old fan was removed to install the new fan onto the rear panel See the note above Grasp the power connector attached to the fan assembly and push it onto the power outlet located to the left of the fan on the rear panel Specifications MECHANICAL Dimensions 1RU x 17 60 W 447 mm x 10 D 254 mm without fiber support 1RU x 17 60 W 447 mm x 20 25 D 515 mm with fiber ...

Page 27: ...13 LUMO User Manual 50 60 Hz 150 W max Ambient Temperature 40 C max COOLING Fans 1 on frame removable COMMUNICATION Connectors RJ45 2 Compliant to 10BaseT 100BaseTx ...

Page 28: ...14 LUMO Housing Frame Specifications ...

Page 29: ...low leaving the chassis and the speed status of the fan and reports it on a single bi color front panel LED It also carries white LEDs to illuminate the LUMO chassis front panel Features Simple LUMO chassis health monitoring card Monitors the presence and voltage levels of the power supplies Monitors the chassis fan speed Monitors the temperature of the air flow leaving the chassis Convenient fron...

Page 30: ...he door and push the door mounting brackets back into the frame 2 Hook your finger over the plastic diffuser mounted at the front of the card and pull out gen tly until the card is released from the rear connector then slide the card out of the frame 3 Slide the new card into the controller slot and push gently on the card edge to engage the rear connectors 4 Pull the door mounting brackets back o...

Page 31: ...Status Priority Class LED Chassis temperature over limit 1 Critical Flashing RED Frame fan stopped 2 Critical Flashing YELLOW 12VA or 12VB missing with PSUA or PSUB present 3 Redundancy problem RED Frame fan low speed 4 Maintenance problem YELLOW All good All good Green The front LED can display only one alarm status so it displays only the highest priority For example if the fan is at low speed i...

Page 32: ...18 Status Card Specifications Specifications PROCESSING PERFORMANCE Microcontroller ARM Cortex M3 Latency 1 second Power 1W ...

Page 33: ...or control and alarm infor mation entering and leaving the frame The LUMO CPU ETH controller features two Ethernet ports for system wide monitoring and control of the frame using Miranda s control solutions or a third party monitoring system This controller card is compatible with the TCP IP protocol and can support polling or report on error modes unsolicited messaging Features Dual Ethernet RJ 4...

Page 34: ... by the LUMO CPU ETH controller provides the only means of configuring the IP address for the controller card IP Configuration Use of this page is essential for the initial configuration of the device or re configuration after a reset in order to set it up so it can be accessed via iControl on the local area network LUMO CPU ETH controllers are shipped from the factory with the following IP config...

Page 35: ...21 LUMO User Manual 3 Start a browser on the stand alone computer and browse to the LUMO s factory IP address as given above The LUMO s web page will open in the browser ...

Page 36: ...ve the digits 0 through 9 and the hyphen DHCP Disabled for this controller IP address Enter an address appropriate for the local network Network Mask Enter a mask value appropriate for the local network Gateway Enter a gateway address appropriate for the local network 6 Click the Apply button to save your changes 7 Disconnect the stand alone computer from the LUMO The LUMO frame is now ready to be...

Page 37: ...e reset at any time while the LED is flashing by releasing the button 3 Once the LED has stopped flashing the LUMO CPU ETH will reboot and the IP address along with other on board parameters will be reset to its factory values 4 Follow the steps in IP Configuration on page 20 to set the IP address to the required value If you can connect to the LUMO CPU ETH controller through the network you can r...

Page 38: ...ontrol In iControl Navigator or iControl Websites double click on the icon of the controller to open its control panel LUMO CPU ETH controllers are identified as LUMO Controller in the Type column of the iControl Navigator window For convenience enter a descriptive Label in the Info panel of the card to make it easy to locate this specific frame controller amongst those in the list See Identifica ...

Page 39: ...s so it displays only the highest priority For example if there is an internal error it should display RED But if at the same time the chassis fan has failed then the LED will display FLASHING RED Be aware that a high priority alarm can mask a lower priority one Configuring the LUMO CPU ETH Controller This section introduces the operating features of the LUMO CPU ETH controller and describes how t...

Page 40: ...type a descriptive name for this LUMO CPU ETH controller Comments type any desired text The remaining data boxes show manufacturing information about this card Three buttons in the panel give access to other information Details Reports the Firmware version service version and panel version for this card Advanced Shows the Miranda LongID for this card The Miranda LongID is the address of this LUMO ...

Page 41: ...the frame In addition to the information displayed on the Card Front Status LED see page 25 status infor mation acquired by the controller can be viewed in the iControl interface and on the local controller display through the menu The iControl interface always displays two icons in the upper left of the window These report the status of the frame s two power supplies The graphic shows the possibl...

Page 42: ...ol Interfaces Status Frame Select the Frame tab to see a report on the status of the frame s CPU fans and power supplies Status Network Select the Network tab to see a report on the status of the two Ethernet ports on the LUMO CPU ETH card ...

Page 43: ... for all cards installed in the LUMO frame Note that in the LUMO frame only slots 1 to 9 are available For a more detailed report on the status of a specific card open that card s control panel in iControl Status LUMO CPU ETH Resource Usage Select the Advanced tab to view a report on the usage of the controller card s resources ...

Page 44: ...s is reported in the data box The MAC address is not user configurable Data Restoration Many of the LUMO series cards that can be installed in the LUMO frame are complex and have a lot of data stored on board related to their configuration and parameter values The LUMO CPU ETH controller provides a backup of this data which can be restored to the card when needed This is valuable if the card is in...

Page 45: ... was saved For automatic restore and save Click the Restore Point button and view the Config tab Restore The LUMO CPU ETH card can be set up to automatically update a card when it is inserted in a slot previously occupied by a card of the same type whose data was saved Thus a new card can be configured automatically to replace the card that was removed saving a lot of time when cards are swapped C...

Page 46: ...y Monthly Week Week1 Week2 Week3 Week4 Last Week Day Sunday Monday Tuesday Wednesday Thursday Friday Saturday Factory Alignment There may be times when the LUMO CPU ETH settings have been adjusted and it is useful to restore them to a normalized condition The LUMO CPU ETH controller maintains a Factory Default alignment in its memory to which it can be restored at any time Note Ethernet settings a...

Page 47: ...teed Note there is no backup battery for the time circuit so the time must be reset any time the card is powered down NTP IP address Click the Enable NTP box to use an NTP Network Time Protocol source Enter up to three IP addresses of NTP servers TheLUMO CPU ETH card will use the first source of valid time it finds in this list Alarms The LUMO CPU ETH controller generates alarms for the frame in w...

Page 48: ... bottom of the Status Name column GSM Contribution This column allows configuration of the contribution of each individual alarm to the GSM Alarm Status associated with this card GSM is a dynamic register of all iControl system alarms and is also an alarm provider for external applications The possible values for this contribution are related to the Overall alarm contribution If the Overall alarm ...

Page 49: ...or more destination controllers from the list in the window by clicking in the checkboxes or all of them by clicking in the All checkbox Get alarm keys Click this button to open a save dialog where you can save a file containing a list of all alarms on this controller and their current values along with an Alarm Key for each The alarm keys are useful for system integration and troubleshooting The ...

Page 50: ...36 LUMO CPU ETH Controller Card Control Interfaces Specifications System Interfaces Status LED Power ON and System Status Ethernet Ports 2 IEEE802 3 10 100 Base T on RJ45 Power 3W ...

Page 51: ...compressed bit streams DVB ASI The series supports any data rate within the range of 19 4 Mbps to 2 97 Gbps and provides a reclocked serial digital video from 270Mbps to 2 97 Gbps The FIO 911 series offers three different configurations Quad fiber Tx with two dual optical transmitters Quad fiber Tx CWDM with two dual high power optical transmitters Quad fiber Rx with two dual optical receivers The...

Page 52: ...FIO variant and each status LED is labeled The function of the rear panel connectors depends on the FIO 911 variant that is installed and is identified by a lexan that slips over the connectors on the rear panel Lexans are supplied for both BNC and DIN versions of the frame Installing cards and SFP modules See Installing Cards in the LUMO Frame on page 8 for detailed instructions for installing th...

Page 53: ...t the second outputs A2 B2 C2 D2 are only available on the LUMO DIN frame Card Front Status LEDs These LEDs monitor the status of the optical inputs to the FIO 911 Quad Rx Green Optical signal OK Yellow No lock Flashing Yellow Input level too high or too low Red No signal Flashing Red SFP not present or SFP not detected or hardware failure ...

Page 54: ...onverted and sent to the SFP transmitter For the DIN frame only each electrical input is also reclocked and sent to the matching electrical output on the rear panel The FI0 911 4T S13 LC Quad Transmitter includes two SFP TT S13S13 LC modules The front panel and rear lexans DIN and BNC for this model are shown here Lexan for DIN frame Lexan for BNC frame The functional block diagram of the FIO 911 ...

Page 55: ...rted and sent to the SFP transmitter For the DIN frame only each electrical input is also reclocked and sent to the matching electrical output on the rear panel The two signals entering each CWDM transmitter module are modulated at different wavelengths The model number for this device identifies the two included SFP high power CWDM trans mitter modules by specifying the wavelengths of their outpu...

Page 56: ... the two FIO series products Color coding for CWDM modules is shown in the above table The functional block diagram of the FIO Quad High Power CWDM module is shown here Note that the electrical loop outputs are only available on the LUMO DIN frame Card Front Status LEDs These LEDs monitor the status of the electrical inputs to the FIO 911 Quad High Power CWDM Tx Green SDI signal OK Yellow No lock ...

Page 57: ...n iControl Navigator shown below or iControl Websites double click on the icon of an FIO 911 card to open its control panel For convenience enter a descriptive Label in the Info panel of the card to make it easy to locate this specific card amongst those in the list See Identification and Information on page 48 for instructions The iControl panel for the FIO 911 card displays a series of buttons d...

Page 58: ...er supplied informa tion read from the module Data about the two optical channels is monitored on the card and reported in the SFP Info table Temperature C Voltage V Optical Power dBm and Wavelength nm Reclocker and Optical The Reclocker and Optical window allows the user to choose whether the signal reclockers at the inputs are ON or BYPASSED Reclocker control is provided for both electrical and ...

Page 59: ... can be resized if needed It allows the alarm reporting of the LUMO CPU ETH to be configured The panel is organized in columns Status Name This contains an expandable tree listing all the alarms reported by this FIO 911 card Each alarm name includes an icon that shows its current status Green OK Red Alarm set Black Alarm not applicable in this case e g there is no SFP for inputs A and B so all ala...

Page 60: ...nfiguration of the contribution of each individual alarm to the GSM Alarm Status associated with this card GSM is a dynamic register of all iControl system alarms and is also an alarm provider for external applications The possible values for this contribution are related to the Overall alarm contribution If the Overall alarm contribution is selected as Disabled the GSM alarm contribution can be s...

Page 61: ...a level to all alarms in that column simultaneously Once the alarms are configured you may accept the changes or discard them Log Events iControl maintains a log of alarm events associated with the card The log is useful for trouble shooting and identifying event sequences Click in the checkbox to enable logging of alarm events for each individual alarm At the bottom of the window are several othe...

Page 62: ... without applying any changes and leaves the previous settings intact Identification and Information Click the Info button The FIO 911 card is accessible on a network and must be identifiable in order to function in the iControl environment The identification data is entered in the iControl INFO control panel This panel also shows other data that is not user adjustable You can enter the following ...

Page 63: ...Control network Remote System Administration Opens the Joining Locators data box which lists remote lookup services to which this FIO 911 is registered Add Force the iControl service for this FIO 901 to register itself on a user specified Jini lookup service using the fol lowing syntax in the data box jini ip_address where ip_address is the ip address of the server running the lookup service e g R...

Page 64: ...oss 15 dB for up to 1 5 GHz 10 dB from 1 5 GHz to 3 GHz Cable length 100m at 3G 150m at HD 350m at SD ELECTRICAL OUTPUT Signal 3G HD SD SDI SMPTE 424M 292M and 259M C compliant Supported data rates Reclocker bypassed all rates between 19 4 Mbps and 3 Gbps Reclocked data at 270 1483 5 1485 2967 2970 Mbps EN50 83 9 DVB ASI 270 Mbps Return loss 15 dB for up to 1 5 GHz 10 dB from 1 5 GHz to 3 GHz Jitt...

Page 65: ...mpliant RX CHANNEL PATHOLOGICAL BITSTREAM Sensitivity between 1260 and 1610 nm SD HD and 3 Gbps 22 dBm Tx CHANNEL 1310 nm Transmit power 5 dBm to 0 dBm Laser type Fabry Perot Tx CHANNEL CWDM Transmit power 0 dBm to 4 dBm Laser type DFB Distributed Feedback PROCESSING PERFORMANCE Signal path 10 bits Latency 6 ns Power 4W ...

Page 66: ...52 FIO 911 O E and E O Converters Specifications ...

Page 67: ... class 1 laser which emits invisible radiation whenever the module is powered up Because the SFP is hot swappable the mod ule may be powered up as soon as it is installed DO NOT LOOK INTO AN OPERATING SFP MODULE S CONNECTORS AS EYE DAMAGE MAY RESULT The SFP module is sensitive to electrostatic discharge ESD It is recommended that you use an ESD preventive wrist strap grounded to the Lumo chassis w...

Page 68: ...with the tab side of the socket 3 Slide the module straight into the socket and push gently until it clicks into position Connecting the fiber optic cables 1 Remove the dust plug from the SFP module if present 2 Verify that the exposed end of the optical fiber in the LC connector is clean 3 Carefully remove any debris if necessary 4 Plug the LC terminated fiber optic cable into the SFP module ...

Page 69: ... occur 2 Insert a dust plug into the SFP module Removing an SFP module 1 Move the bale clasp lever to the open position 2 Grasp the SFP module between your thumb and fore finger and pull it straight out of the slot Do NOT pull on the bale clasp lever to remove the mod ule as it is easily damaged You may find that you need to wiggle the module or perhaps push it into the slot a bit before it will r...

Page 70: ...available to help the fiber user maintain good fiber network performance For best results it should be possible for the user to perform a visual inspection of the fiber ends to verify cleanliness Miranda strongly urges all users to select a cleaning method that meets their needs and to use it rigorously and consistently A few tips Always use a dust plug in an empty fiber receptacle to keep airborn...

Page 71: ...ain a local phone number for the support center nearest you please consult the Contact Us section of Grass Valley s website www grassvalley com An online form for e mail contact is also available from the website Corporate Head Office Grass Valley 3499 Douglas B Floreani St Laurent Quebec H4S 2C6 Canada Telephone 1 514 333 1772 Fax 1 514 333 9828 www grassvalley com ...