KAYENNE K-FRAME — Installation & Service Manual
147
Switcher Relay Tally Configuration
4.
Touch a
Tributary
button on the right.
5.
Touch an
ME
or
PGM/PST
button on the left.
6.
Touch a LAP 1-4 button to assign that look ahead to that Tributary.
Figure 96. Look Ahead Preview Tally—Six-Keyer System
7.
through
to assign all the desired look aheads to the
calculation.
8.
To activate this calculator, touch the
Calc On
button so it is highlighted.
Note
Though the calculator is activated, it will not actually affect Video Processor
Frame relay contacts until that calculator has been assigned to a Tally Group
(see
Creating a Bus Relay Tally Calculator
Bus tallies report what source(s) are currently selected on a particular set of
buses, and does not trace tributaries upstream.
Use the Look Ahead Preview procedure above, but choose PGM/PST, ME,
or Aux, on the left, and then select the desired bus in the center of the
screen. Repeat for all the buses you wish to tally.