background image

66

Router Control Configuration

Setting Up iRouter for the GV Node

The Router Manager Configurator window opens.

3 Click  the 

Physical Routers folder

 to open the physical routers management window on 

the right side of the panel.

4 Click 

Add Router.

The physical router configuration panel is displayed.

Summary of Contents for grass valley GV NODE

Page 1: ...User Manual M6103 9800 100 2016 07 15 GV NODE IP AGGREGATION PROCESSING AND EDGE ROUTING PLATFORM...

Page 2: ...es to use their product manuals for their own internal business use Manuals for Grass Valley products may not be reproduced or transmitted in any form or by any means electronic or mechanical includin...

Page 3: ...king any other equipment connections Identifies an external protective grounding terminal which may be connected to earth ground as a supplement to an internal grounding terminal Indicates that static...

Page 4: ...id or aerosol cleaners use only a damp cloth Dangerous voltages may exist at several points in this equipment To avoid injury do not touch exposed connections and components while power is on High lea...

Page 5: ...ctrostatic Discharge ESD Protection Electrostatic discharge occurs when electronic components are improperly handled and can result in intermittent failure or complete damage adversely affecting an el...

Page 6: ...e bo tier de l quipement cette tension peut tre suffisante pour constituer un risque de d charge lectrique Avertit l utilisateur l op rateur ou le technicien de maintenance que des instructions import...

Page 7: ...afin de ne pas endommager les connecteurs Coupez l alimentation avant de nettoyer l quipement Ne pas utiliser de nettoyants liquides ou en a rosol Utilisez uniquement un chiffon humide Des tensions d...

Page 8: ...modules d alimentation auto adaptables v rifiez la configuration de chacun des modules d alimentation avant de les mettre sous tension Assurez une ventilation ad quate Pour viter toute surchauffe du p...

Page 9: ...t ne remplacez la pile que par une pile du m me type recommand e par le fabricant Mettez les piles usag es au rebut conform ment aux directives du fabricant Avant de vous d faire de l quipement assure...

Page 10: ...ay cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the i...

Page 11: ...572 2011 Grass Valley Grass Valley Technical explanations This statement is based on the information provided by our suppliers of components and collected through our Grass Valley s environmental mana...

Page 12: ...xii Notices...

Page 13: ...uration 11 Configure the Controller 11 Configure the Frame Reference 13 Configure the Fabric Module 13 2 Configuring Your GV Node 15 CPU ETH3 Controller User Interface 15 Identification 15 Status Moni...

Page 14: ...ace 48 The iControl Service Panel 49 Identification 49 Status 51 Input Configuration SDI 52 Input Timing 55 Input Status 55 Output Configuration SDI 56 Output Timing 58 Output Status 59 GV Node Manage...

Page 15: ...follows Installed in a rack Connected to your local IP network Registered to iControl Preliminary configuration completed for CPU ETH3 controller IFM 2T fabric module XIO 4901 SDI I O modular cards I...

Page 16: ...ncorporates 12 40 GigE aggregation ports available on the rear panel These ports are accessed by 144 outputs and 144 inputs to the fabric card in order to interface multiple GV Nodes together via Poin...

Page 17: ...TH 1 2 Dual GigE Ethernet ports for connection to external control systems e g iControl GV Convergent on RJ45 connectors ETH2 for future use MEDIA PORT GigE 10 GigE 1 2 Dual streaming ports for intern...

Page 18: ...controller The two ports carry exactly the same signal The MON 2 output is placed near the modular card slots and could be connected to a Grass Valley SME 1901 Streaming Media Encoder located in slot...

Page 19: ...rol panel provides a touch screen interface and is accessible through an aperture in the GV Node front door Local Control Panel Home screen The IP addresses of control ports ETH1 and ETH2 are displaye...

Page 20: ...EL to access the next menu level When a parameter value is shown on the display modify the value by using the and buttons and then touch SEL to apply the value Touch ESC to go back to the previous men...

Page 21: ...integrated frame reference the IFM 2T fabric module and the modular cards cannot be configured through this interface See Configure the Controller on page 11 for instructions on accessing and using th...

Page 22: ...onfigure your GV Node Notes For detailed information about iControl refer to the iControl User Guide available from the Documentation Library section of Grass Valley s website Fordetailedinformationab...

Page 23: ...lue unchanged Note Touching ESC when the input focus is in the first position returns you to the previous menu level 5 Once you have accepted all values in the desired address touch ESC repeatedly to...

Page 24: ...nfiguration tab click Add The Target Information window opens 5 In Target Information enter the IP address that you have given your GV Node and a Densit name for the GV Node e g DNAME 6 Click OK The T...

Page 25: ...ces make up the iControl presence of your GV Node GV Node Initial Configuration You will configure three elements of your GV Node in this initial setup Configure the Controller on page 11 Configure th...

Page 26: ...vigation area The Time Date setup page appears If you have an NTP server s IP address enter it and select Enabled If you do not have an NTP server s IP address manually enter the current date and time...

Page 27: ...ference module s iControl panel opens 2 To set the timecode and reference sources a Click the Input tab b In the Reference Source list select Auto c In the Timecode Source list select Auto Changes are...

Page 28: ...V Node Manager associated with your GV Node and double click its icon The GV Node s GV Node Manager panel opens Note In the presence of multiple GV Node managers locate yours by checking the Comments...

Page 29: ...e See CPU ETH3 Menu on page 63 for a complete listing of the local control menu Summary Identification 15 Status Monitoring 17 Network Settings 20 SNMP Functionality 21 Data Restoration 21 Factory Ali...

Page 30: ...dentification FrameControllerDNAME Short Label 8 character short label used in iControl Frame Co Source ID Any text no text Comments Any text Densite Frame Service The remaining data boxes show manufa...

Page 31: ...the data throughput of all cards installed in the frame In addition to the status displayed by the CTRL icon on the local control panel screen see page status information acquired by the controller c...

Page 32: ...Monitoring Status Frame Select the Frame tab to see a report on the status of the frame s CPU fans and power supplies Status Network Select the Network tab to see a report on the status of the two Et...

Page 33: ...nd Tx and receive Rx data rates and speed for all cards installed in the GV Node frame For a more detailed report on the status of a specific card open that card s control panel in iControl Status Adv...

Page 34: ...name is the unique name by which this GV Node CPU ETH3 is known on the network The hostname should be 15 characters or less and may contain only the ASCII letters a through z case insensitive the digi...

Page 35: ...o three target IP addresses can be entered in the menu via the SNMP OPTIONS item Data Restoration Many of the modular cards that can be installed in the GV Node frame are complex and have a lot of dat...

Page 36: ...slot is the same type as the card that was there when the data was saved For automatic restore and save 1 Click the Restore Point button and view the Config tab Restore The CPU ETH3 can be set up to...

Page 37: ...he Restore Points menu item Factory Alignment There may be times when the CPU ETH3 settings have been adjusted and it is useful to restore them to a normalized condition The CPU ETH3 controller mainta...

Page 38: ...in these boxes to change the current setting If an automatic update via NTP is not enabled the clock will continue to run using an on board reference but precision is not guaranteed NTP IP address se...

Page 39: ...ome screen status display and the status icon in the top left of the iControl window The alarms are reported to the iControl network and can be reported locally on the frame s GPI port GPI reporting c...

Page 40: ...nel Using the Menu Access the Alarm Report menu item and scroll through the list of available alarms setting each to OFF or to report through GPI Use the GPI Report item to turn GPI reporting on or of...

Page 41: ...select the reference source 1 Select the Input tab 2 Click the Reference Source pulldown 3 Click to select the reference source Selection Detail Auto Use the External reference if it s not available...

Page 42: ...ame frame some cards can work in 25Hz frame rate and other cards in 29 97Hz The phase relation between these two frame rates will be arbitrary thus the name free run Timecode To select the timecode so...

Page 43: ...reference all information extracted from the input is out of phase and the card may flag errors even if there are none To configure timecode logging 1 Select the Alarms tab 2 Select the checkboxes to...

Page 44: ...mn b Click to select the appropriate alarm status from the drop down list All alarms in the column will be set to the selected status c Repeat steps a and b for the GSM contribution column 5 Click OK...

Page 45: ...Short Label The short form label that iControl uses in some cases 8 characters Source ID A descriptive name for this frame reference Comments Any desired text The remaining data boxes show manufactur...

Page 46: ...The LongID is the address of this frame reference in the iControl network Remote System Administration Opens the Joining Locators window which lists remote lookup services to which this frame referen...

Page 47: ...42 Lane Statistics Reporting 43 Lane Statistics Reporting 43 Timing 44 Alarms 45 User Presets 46 Factory Configuration 47 Edge Device Control 48 In iControl Navigator or iControl Websites double clic...

Page 48: ...rol applications Short Label The short form label that iControl uses in some cases 8 characters Source ID A descriptive name for this IFM 2T Comments Any desired text The remaining data boxes show man...

Page 49: ...Joining Locators window which lists remote lookup services to which this IFM 2T is registered To add additional services 1 Click Add 2 Enter the IP address of a server running a Jini look up service u...

Page 50: ...our GV Node Options When an error is flagged an error status message will be shown beneath the dashboard icons Multiple error messages will cycle in the display You can always check the current status...

Page 51: ...option is active Port and Lane Configuration Each 40GbE port incorporates four 10GbE lanes and each of these can be configured individually Note The GV Node reserves bandwidth for each enabled lane s...

Page 52: ...use the Enable All Lanes or Disable All Lanes checkboxes as a shortcut 3 Click Apply to confirm or Cancel to discard your changes To set the Source IP Address for each Lane 1 Click Global Config and...

Page 53: ...ream destination address and port 1 Click TX Stream Config 2 Click on the tab corresponding to the 40GbE port whose transmit streams you want to configure 3 Enter a Stream Address and Stream Port for...

Page 54: ...dress To set the Receive Stream source address and port 1 Click RX Stream Config 2 Click on the tab corresponding to the 40GbE port whose source streams you want to configure 3 Enter information for e...

Page 55: ...dressing Utility 1 Click Global Config and select the Bulk Addressing tab 2 Use the pulldowns at the top to identify the range of Ports Lanes and Streams that you want to address 3 Click a radio butto...

Page 56: ...in each of the twelve 40GbE ports 48 lanes in all can be viewed in the Lane Status panel To view the status of a lane 1 Click Lane Status panel 2 Select the tab for the 40GbE port containing the Lane...

Page 57: ...r each of the 12 lanes 40GbE port 10GbE lane Tx Rx one row per lane not per stream for each Bandwidth Bytes throughput in Mbps Packets number of packets passed Error number of errors counted All dynam...

Page 58: ...b 2 Select the Switching Alignment plane using the pulldown list Alignment Plane Details Module Slots Align on the SDI inputs from the XIO 4901 cards Aggregation Ports Align on the IP inputs from the...

Page 59: ...s The fabric module generates alarms which are sent to the GV Node controller card when error conditions are detected These alarms are used to set the control panel status display and the status icon...

Page 60: ...dow open or Cancel to discard the changes and close the window See Alarm Configuration on page 60 for a more detailed description of the contents of this panel User Presets The IFM 2T has 5 memory reg...

Page 61: ...set of factory specified settings in memory and can be restored to that state at any time You can select which groups of parameters are restored To reset the IFM 2T to the factory default status 1 Cli...

Page 62: ...rnal control of the RX streams Edge Device Control RX Stream Addressing Disabled RX stream addresses are static set in the RX Stream configuration page Enabled RX stream addresses are dynamically conf...

Page 63: ...ntrol Service Panel Locate your XIO 4901 in iControl Navigator and double click its icon to open the service panel Identification The user can enter labels and comments to make this XIO 4901 easy to i...

Page 64: ...ol applications Short Label The short form label that iControl uses in some cases 8 characters Source ID A descriptive name for this XIO 4901 Comments Any desired text The remaining data boxes show ma...

Page 65: ...ning Locators window which lists remote lookup services to which this XIO 4901 is registered To add additional services 1 Click Add 2 Enter the IP address of a server running a Jini look up service us...

Page 66: ...tion via the controller rear panel Green Ehernet OK Red Ethernet fault 6 Card health Green Card OK Red Card failure 7 Processing Mode Green Normal operation Yellow Test signal activated on at least on...

Page 67: ...Use the Format pulldown to select one of these supported formats 525i 625i 1080p59 94A 1080p50A 1080i59 94 1080i50 720p50 To select the input format for all nine SDI Inputs at once 1 Click Input Confi...

Page 68: ...ncel to leave the color unchanged To select the Output on Error for all nine SDI Inputs at once 1 Click Input Config and select the All tab 2 Click on the Output on Error Mode pulldown 3 Click to sele...

Page 69: ...he the detection circuitry to lock it only to have the signal drift away from the reference unlocking the input circuits The lock unlock cycle will raise error messages and interfere with system opera...

Page 70: ...the Name data box To select how the output format of the XIO 4901is determined 1 Click the Format Mode pulldown 2 Click to select the desired format mode Selection Details Follow source format The XI...

Page 71: ...d a standard color bar to the SDI output RGB value Feed a full frame color patch to the SDI output To choose the color for the RGB value 1 Click the color patch in the screen beside the Output on Erro...

Page 72: ...atch individually for each of the nine outputs as per To choose the color for the RGB value on page 54 You can use the color patches here instead of returning to the individual tabs they are interconn...

Page 73: ...the Total Delay data window Output Status You can check the status of the nine SDI outputs by selecting Output Status GV Node Manager The GV Node Manager manages inputs and outputs between the IRM 2T...

Page 74: ...rom the fabric module XIO 4901 The available choices depend on whether the MDX option is activated on the XIO 4901 card Alarm Configuration All modules with an iControl interface provide an Alarm Conf...

Page 75: ...LED status is shown at the bottom of the alarm tree in the Status Name column This column is not shown in all cases Overall Alarm This column allows configuration of the contribution of each individua...

Page 76: ...the column beside the card name to select all alarms At the bottom of the window are several other controls Copy to other cards 1 Click this button to open a panel that allows the alarm configuration...

Page 77: ...63 GV Node User Manual Local Control Menus CPU ETH3 Menu Continued...

Page 78: ...64 Configuring Your GV Node CPU ETH3 Menu...

Page 79: ...umentation for these products available on the Grass Valley website www grassvalley com Setting Up iRouter for the GV Node The following procedure is a GV Node specific version of a broader procedure...

Page 80: ...r for the GV Node The Router Manager Configurator window opens 3 Click the Physical Routers folder to open the physical routers management window on the right side of the panel 4 Click Add Router The...

Page 81: ...ode into the Router host name IP address data box 9 Type 5194 in the UDP IP port data box 10 Click Add Level The Physical Level Configuration window opens 11 If you want to name the level differently...

Page 82: ...red the GV Node as a physical router with a video level in iRouter Creating Logical Routers The next step in setting up iRouter to manage the GV Node is to establish a logical router or routers that r...

Page 83: ...n a local phone number for the support center nearest you please consult the Contact Us section of Grass Valley s website www grassvalley com An online form for e mail contact is also available from t...