10
Getting Started
Connecting the GV Node to your Network
Connecting the GV Node to your Network
To connect the GV Node to your network
1 Connect CONTROL PORT ETH1 to your local TCP/IP network via an RJ45 connector.
2 Connect a local reference signal (black burst or tri-level sync) to REF IN 1.
You may use either of the two connectors; the second connector is a loop-through and
does not require termination.
Registering your GV Node to iControl
To register your GV Node to iControl
1 Open iControl Navigator.
2 In
Logical
view, open the
Managers
folder.
3 In the
Managers
folder, locate the Densité Manager associated with your application
server and double-click its icon.
The Densité Manager window opens.
4 In the
Configuration
tab, click
Add
.
The
Target Information
window opens.
5 In
Target Information
, enter the IP address that you have given your GV Node, and a
Densité name for the GV Node (e.g., DNAME).
6 Click
OK
.
The
Target Information
window closes.
Your GV Node appears in the
Configuration
tab.
The GV Node’s status is Online, and its icon is green.
7 Close the Densite Manager window.
The frame and its cards are now accessible from iControl Navigator.
8 Look for these four devices in iControl Navigator :
• The GV Node frame controller.
By default, the controller is identified as follows:
DNAME is the Densité name you created in
• The GV Node frame reference module, incorporated into the controller, but with its
own control panel.
Label
Frame ControllerDNAME
Short label
Frame Co
Type
GV Node Frame Controller
Comments
Densite Frame Service
Frame
DNAME
Label
Frame Reference
Short label
Frame Re
Type
Frame Reference