51
CopperHead 3404
User Guide
• 12 - Ethernet Connector - 10Bt/100Bt capable:
Designed to carry IP traffic data between the Base Station and the Camera Unit. A
laptop PC or other device such as a Wireless Access Point can be connected to the
Production Environment IP network.
• 13 - VBS Out:
BNC Connector -Typically used for SD Monitoring Video return from the Camera.
• 14 - VBS In:
BNC Connector - Typically used to send SD return video to the camera - an example is
monitor out from the Production Switcher.
• 15 - SDI Out 1 & 2 (this carries the HD feed (not the 4K-3G feed) from the camera):
BNC Connectors - Two identical video feeds from the camera - typically one may be
used for local HD monitoring and one is fed to the Production Switcher environment.
• 16 - SDI In:
BNC Connector - Typically used to send HD return video to the camera - an example is
program out from the Production Switcher.
• 17 - 4K- 3G/HD/SD SDI Connectors (this carries the four 4K signals from the camera)
BNC Connectors
• 18 - Audio In- Multi-Pin Connector:
DB25 - 25 pin Connector follows the Tascam TDIF standard. The CopperHead 3404
Transceiver System accommodates up to two Audio Channels at Line Level. This
connector handles return audio to the Camera location as well as intercom Program
Audio. Please see
on page 100 for sample wiring.
• 19 - Audio Out- Multi-Pin Connector:
DB25 - 25 pin Connector follows the Tascam TDIF standard. The CopperHead 3404
Transceiver System accommodates up to two Audio Channels at Line Level. This
connector handles Program audio from the Camera location (see
on page 100 for sample wiring).
• 20 & 21 - Intercom Connectors #1 & #2:
XLR 3 pin or 5 pin Connector depending on configuration. One of three options will be
installed (4-wire intercom, RTS, or Clear-Com).
• 23 - 12V Terminal Block:
Terminal Block - bare wire connector. This can be used in place of the ADAP power
connection in installations that have 12V power distributed as part of their
infrastructure. Do not use this at the same time as the ADAP power connection.
• 24 - ST Fiber Connectors (used in place of connector 4):
Two ST Connector receptacles - Used as the Fiber Optic connection typically when
infrastructure wire or with one of the two external power supply option (MPS or HDX
Power Adaptors).
• 25 - Molex Power Connectors (used in place of 4 and only if so configured with ST
Fiber Connectors):
5 Conductor Molex Connector - Used to provide power to the Hybrid Fiber Optic Cable.
Typically installed with infrastructure wiring with cable leading from Molex connector
to a panel mounted OpticalCON receptacle.
Summary of Contents for Grass Valley CopperHead 3404
Page 1: ...CopperHead 3404 User Guide M4051 9900 103 6 April 2016...
Page 6: ...vi Table of Contents...
Page 12: ...6 About CopperHead 3404 Product Returns...
Page 46: ...40 Feature Detailed Description HDX Power Unit...
Page 82: ...76 Operation of CopperHead 3404 Transceiver System Troubleshooting...
Page 86: ...80 Specifications...
Page 101: ...95 Wider Illustrations...
Page 105: ...99 Camera Remote Control Cables...