SL2: 1063 PROGRAMMING AND OPERATION
3-4
Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL294
Setup / Entrance Operation
Chapter 3 Operator Interface/Programming
Setup
E-1063
Screen Key
•
Values to the right of the
YES/NO toggles are measured
in seconds
Fields to the right of “Entrance Operation” allows changing the name of the function.
ON and OFF Columns: There are two fields under these headings. The left columns are YES/NO toggles and the
right columns display values in seconds. Seconds values may be changed in increments of tenths of a second.
Fields to the right of “LINK MISC OUTPUT” allows changing the Output of this function to any of the MISC outputs
(1 – 8). Named Outputs 1 – 8 may not be used by this function.
Entrance Operation 2 has an additional field that allows it to be configured as a Entrance Door Up function. It
toggles back and forth as shown
/
.
This feature is DOOR UP ONLY and may not be used for Door Down control. This feature would not be used if
system is equipped with an On-Board Door Control.
This system is equipped with 3 Entrance Functions.
Each of these functions could utilize one, all or any combination of ON conditions. The ON condition that is met
first will turn on the functions output.
Each of these functions could utilize one, all or any combination of OFF conditions. The OFF condition that is met
first will turn off the functions output.
These functions will not operate on the vehicle unless toggled to YES in the Package Setup.
When configuring an Entrance Operation, it is a good practice to name the Output first, then name the Function
and finally make sure that the Function is linked to the proper Output.
Pull-In: Occurs as soon as the Loader has the Package value or cycle just started. The Package is officially
started as soon as Entrance Operation 1 shifts the Package number from the Loader to the wash.
Enter 1 Photo, Enter VPS, Enter Door: These are all inputs that require a “light-operated” Photo-Eye (i.e. the
input turns off when the vehicle blocks the Photo-Eye beam). The ON condition for these is when the input turns
off. The OFF condition is when the input turns back on.
Treadle: Both ON and OFF conditions are referred to when the vehicle is in the Wash position (typically between
VPS Photo-Eyes.
Max-Time: This is an OFF condition only. It’s a maximum time that a function will stay on once it turns on.
Pump: This is the pump speed measured in percent for Entrance Operation that is utilizing the 25HP VFD Pump.
Only Entrance Operation 1 or Entrance Operation 3 may utilize this pump.
Summary of Contents for SABER SL-2
Page 2: ......
Page 4: ......
Page 5: ......
Page 6: ......
Page 10: ......
Page 16: ......
Page 18: ......
Page 21: ...Chapter 3 Operator Interface Programming Chapter 3 Operator Interface Programming ...
Page 22: ......
Page 38: ......
Page 46: ......
Page 47: ...Chapter 5 Techniques in Programming Chapter 5 Techniques in Programming ...
Page 48: ......
Page 51: ...Chapter 6 Techniques in Programming Chapter 6 Faults and Alarms ...
Page 52: ......
Page 63: ...Chapter 8 E 1063 Screen map Chapter 8 E 1063 Programming Screen Map ...
Page 64: ......
Page 65: ...SL2 1063 PROGRAMMING AND OPERATION ...
Page 66: ......
Page 67: ......