Technical data
METPOINT
®
OCV
13
6.2 Evaluation unit with user interface (display)
Dimensions:
230 x 200 x 120 mm (W x H x D)
Weight:
Approx. 3.6 kg
Protection class:
Standard IP 54
Operating temperature: +5..+50 °C
Storage temperature:
+5..+50 °C
Resistance to climatic
conditions:
Rel. humidity
≤
75% annual mean without dew
Power cord:
Max. cladding diameter: 6.5 mm, strand cross: 0.75 mm²,
with safety plug and PE protective earthing
Outputs:
Potential-free change-over contact, 230V/AC 5A or 24V/DC 5A
optional 4….20 mA
Power supply:
Version 1: 230 V AC 50 Hz +/- 10%
Version 2: 115 V AC 60 Hz +/- 10%
Internal fusing:
1.0 A, slow (T1A / 250V)
Max. operating current:
Max. 0.22 A
Power consumption:
Max. 50.6 VA
Memory:
2 GB internal memory
6.3 EU directives and harmonised standards applied
2006/95/EC
Low-Voltage Directive
2004/108/EC
Directive about the electromagnetic compatibility, EMC
EN 61010-1
Safety requirements for electrical equipment for measurement, control and laboratory
use
EN 61326-1
E
lectrical equipment for measurement, control and laboratory use
EMC requirements