EN
Installation and operation manual
DRYPOINT
®
M eco control
19
PDP inlet
Volume flow inlet in ll/min at 7bar
+35 °C,
+20 °C,
+5 °C,
DEC
1-30S
DEC
2-40S
DEC
3-60S
DEC
4-80S
DEC
5-115S
DEC
6-135S
DEC
7-165S
DEC
8-250S
DEC
9-330S
+10°C,
390
520
780
1040
1440
1690
2000
3050
4050
+5°C,
-5°C,
310
410
615
820
1140
1340
1600
2380
3180
+10°C,
0°C,
-10°C,
244
325
495
655
910
1070
1280
1900
2540
+5°C,
-5°C,
-15°C,
208
278
417
556
780
915
1090
1650
2190
0°C,
-10°C,
182
242
364
485
685
805
970
1480
1960
-5°C,
-20°C,
162
216
324
432
615
725
870
1330
1770
-10°C,
-15°C,
149
198
297
396
565
665
805
1230
1630
-15°C,
-20°C,
-26°C,
136
182
273
364
520
610
745
1130
1500
-20°C,
-26°C,
127
169
253
338
484
570
690
1050
1390
-26°C,
118
157
236
315
452
530
640
975
1300
PDP outlet
30
40
60
80
115
135
165
250
330
7 bar
Purge air in l/minute at 7 bar *
* the intrinsic permeability is approx. <5% relating to the purge air volume.
PDP inlet
Volume flow inlet in ll/minute at 6 bar
+35 °C,
+20 °C,
+5 °C,
DEC
1-30S
DEC
2-40S
DEC
3-60S
DEC
4-80S
DEC
5-115S
DEC
6-135S
DEC
7-165S
DEC
8-250S
DEC
9-330S
+10°C,
300
400
601
801
1109
1301
1540
2349
3119
+5°C,
-5°C,
239
316
474
631
878
1032
1232
1833
2449
+10°C,
0°C,
-10°C,
188
250
381
504
701
824
986
1463
1956
+5°C,
-5°C,
-15°C,
160
214
321
428
601
705
839
1271
1686
0°C,
-10°C,
140
186
280
373
527
620
747
1140
1509
-5°C,
-20°C,
125
166
249
333
474
558
670
1024
1363
-10°C,
-15°C,
115
152
229
305
435
512
620
947
1255
-15°C,
-20°C,
-26°C,
105
140
210
280
400
470
574
870
1155
-20°C,
-26°C,
98
130
195
260
373
439
531
809
1070
-26°C,
91
121
182
243
348
408
493
751
1001
PDP outlet
26
35
52
70
100
117
144
218
287
6 bar
Purge air in l/minute at 6 bar *
* the intrinsic permeability is approx. <5% relating to the purge air volume.
PDP inlet
Volume flow inlet in ll/minute at 5 bar
+35 °C,
+20 °C,
+5 °C,
DEC
1-30S
DEC
2-40S
DEC
3-60S
DEC
4-80S
DEC
5-115S
DEC
6-135S
DEC
7-165S
DEC
8-250S
DEC
9-330S
+10°C,
218
291
437
582
806
946
1120
1708
2268
+5°C,
-5°C,
174
230
344
459
638
750
896
1333
1781
+10°C,
0°C,
-10°C,
137
182
277
367
510
599
717
1064
1422
+5°C,
-5°C,
-15°C,
116
156
234
311
437
512
610
924
1226
0°C,
-10°C,
102
136
204
272
384
451
543
829
1098
-5°C,
-20°C,
91
121
181
242
344
406
487
745
991
-10°C,
-15°C,
83
111
166
222
316
372
451
689
913
-15°C,
-20°C,
-26°C,
76
102
153
204
291
342
417
633
840
-20°C,
-26°C,
71
95
142
189
271
319
386
588
778
-26°C,
66
88
132
176
253
297
358
546
728
PDP outlet
23
30
45
60
86
101
124
188
248
5 bar
Purge air in l/minute at 5 bar *