Installation and operation manual
EN
20
DRYPOINT
®
M eco control
PDP inlet
Volume flow inlet in ll/minute at 4 bar
+35 °C,
+20 °C,
+5 °C,
DEC
1-30S
DEC
2-40S
DEC
3-60S
DEC
4-80S
DEC
5-115S
DEC
6-135S
DEC
7-165S
DEC
8-250S
DEC
9-330S
+10°C,
152
203
304
406
562
659
780
1190
1580
+5°C,
-5°C,
121
160
240
320
445
523
624
928
1240
+10°C,
0°C,
-10°C,
95
127
193
255
355
417
499
741
991
+5°C,
-5°C,
-15°C,
81
108
163
217
304
357
425
644
854
0°C,
-10°C,
71
94
142
189
267
314
378
577
764
-5°C,
-20°C,
63
84
126
168
240
283
339
519
690
-10°C,
-15°C,
58
77
116
154
220
259
314
480
636
-15°C,
-20°C,
-26°C,
53
71
106
142
203
238
291
441
585
-20°C,
-26°C,
50
66
99
132
189
222
269
410
542
-26°C,
46
61
92
123
176
207
250
380
507
PDP outlet
19
25
38
50
72
85
104
158
208
4 bar
Purge air in l/minute at 4 bar *
* the intrinsic permeability is approx. <5% relating to the purge air volume.
Product selection:
Example for selection drying system for:
•
Volume flow utilisation air:
180 l/min
•
Operating pressure:
4 bar
•
PDP reduction:
+5 °C to -20 °C
Search in table for performance data 4 bar
Column PDP inlet “+5 °C“ up to the row “-20 °C“ (PDP outlet)
Search for a value in this row which is larger than the utilisation air flow
Column DEC 5-115S fulfils this requirement with nominal value 240 l/minute
Purge air consumption DEC 5-115S:
72 l/minute must be deducted from the inlet volume flow
Max. utilisation volume flow:
168 l/minute
device too small
select larger device DEC 6-135S