CLEARPOINT® V Series Activated Carbon Tower
(Rev. B)
14
6.
MAINTENANCE AND SERVICE
6.1
Maintenance and Service Information
6.1.1 Routine Maintenance
The service must be carried out only by a qualified technician.
Before any service is carried out, always verify that:
+
Depressurize the unit and ensure the unit is isolated from the compressed air system (see page
14)
The personnel that service the machine must wear hearing and eye protection before operating the carbon
tower. Each employee must select a proper personal protection device (PPD) hearing protector such as
earmuffs, ear canal caps or earplugs in order to prevent permanent hearing damage or loss.
DAILY
+
Check the differential pressure of any installed pre and post filtration
+
Check that the tower pressure gauge reads full line pressure
ANNUALLY
+
Replace the pre and post filter elements
+
Check the air quality for oil aerosol and oil vapor content. Replace the activated carbon material in
the tower as necessary
6.1.2 Activated Carbon Replacement
CAUTION:
Activated carbon dust is considered a nuisance dust. Proper precautions should be taken prior to
replacing the desiccant material in the dryer. Please refer to the Material Safety Data Sheet (MSDS).
1.
Isolate and shut down the carbon tower (see page 13).
2.
Place a suitable container at the edge of the drain port on the bottom of the tower that are located on the
bottom.
3.
Open the drain port on the bottom of the tower and catch the activated carbon in the container.
4.
Refill the tower with the recommended type, size and quantity of activated carbon. Only use
manufacturer supplied activated carbon, which is high quality, high capacity activated carbon designed
and sized for the carbon tower.
5.
Replace the drain port using thread sealant.
6.
Carefully knock on the sides of the tower chamber while filling so that the activated carbon will pack
tightly. Some settling may be required in order to fit the specified fill amount into the tower. Tank sizes
may be the same for multiple models, so do not be concerned if the tower is not entirely full.
7.
Activated carbon contaminated with oil or other substances may require different disposal methods and
procedures. Consult the appropriate MSDS and follow all applicable laws and regulations regarding
disposal.