CLEARPOINT® V Series Activated Carbon Tower
(Rev. B)
6
Don’t use water to extinguish fire on the dryer or in the surrounding area
.
2.
INSPECTION AND TRANSPORTATION
All activated carbon towers are tested and inspected at the factory prior to shipping. Thoroughly inspect and verify the
integrity of the packaging upon receipt and note any damage on the freight bill. Place the unit as close as possible to the
installation point before unpacking the contents and inspect for concealed damage. Freight claims are to be filed with
the carrier immediately and the manufacturer’s technical service department notified thereafter.
+
To move the packaged unit, we suggest the use of a suitable crane or forklift. We do not recommend moving the
unit by any hand operated or manual mechanism.
+
Handle with care. Heavy blows could cause irreparable damage.
+
Even when packaged, keep the machine protected from severe weather.
The packaging materials are recyclable. Each material must be properly disposed in a manner complying
with the rules and regulations of the local municipality government.
3.
TECHNICAL SPECIFICATIONS AND GENERAL FUNCTION
3.1
Technical Data by Model Size
CLEARPOINT® V
Model / Size
1000
1200
1500
1900
2300
2800
Flow Rate
scfm
1000
1200
1500
1900
2300
2800
Inlet / Outlet Connection (Flange)
in. 2-1/2
”
2-1/2
”
3
”
3
”
4
”
4
”
Height (A)
in.
86
85
90
78
93
83
Width (B)
in.
24
26
28
36
36
40
Depth (C)
in.
27
28
29
36
35
41
Adsorbent Material
Activated Carbon
1/8”
Total Weight
lbs.
354
428
536
729
853
1105
Maximum Inlet Relative Humidity
%
30
Maximum Inlet Oil Aerosol
Content
mg/m
3
0.01
Minimum Ambient Temperature
°F
40
Maximum Ambient Temperature
°F
120
Standard Inlet Air Temperature
°F
100
Maximum Inlet Air Temperature
°F
120
Standard Air Pressure
psig
100
Maximum Air Pressure
psig
150
Activated carbon tower flow ratings adhere to the following conditions:
+
Inlet Compressed Air Temperature 100 °F (38 °C)
+
Inlet Compressed Air Pressure 100 psig (7 bar)
+
Ambient Air Temperature 100 °F (38 °C)
SCFM is defined as the volume of free air in cubic feet per minute measured at 14.5 psia (1.013 bar) at 68 °F (20 °C)
temperature with 0% relative humidity (0 WVP).