CLEARPOINT® V Series Activated Carbon Tower
(Rev. B)
7
3.2
Correction Factors
Operating Pressure
Correction Factors
60
PSIG
70
PSIG
80
PSIG
90
PSIG
100
PSIG
110
PSIG
120
PSIG
130
PSIG
140
PSIG
150
PSIG
Correction Factor
0.65
0.74
0.83
0.91
1.00
1.12
1.16
1.20
1.25
1.29
How to size the carbon tower capacity for actual conditions: How to select the carbon tower for actual conditions:
ADJUSTED CAPACITY =
ADJUSTED CAPACITY =
Standard Flow Rate x Correction Factor
System Flow Rate ÷ Correction Factor
Example:
Example:
Dryer Model:
CLEARPOINT® V 250
System Flow Rate:
300 scfm
Standard Flow Rate:
250 scfm
Operating Conditions: 130 psig
Operating Conditions: 110 psig
ADJUSTED CAPACITY = 300 scfm ÷ 1.20 =
250 scfm
ADJUSTED CAPACITY = 250 scfm x 1.12 =
280 scfm
Select Model:
CLEARPOINT® V 250