Installation and operation manual
EN
18 BEKOMAT
®
8/9
5. Operation
The following displays show the different system states of the
BEKOMAT
®
.
Normal state:
Normal operation:
• Green LED “Power” lights up:
Voltage OK,
BEKOMAT
®
in operation
Fault state:
• Yellow LED “Valve” lights up:
Filling level reached
Valve opens,
condensate is discharged
The valve opening time varies sensor-controlled (depending on the flow-off speed).
After condensate discharge:
-
BEKOMAT
®
is emptied to maximum extent
- Valve closes in good time
- No unnecessary pressure loss
Alarm state:
ALARM malfunction case:
• Pressure too low to open the valve
• Condensate occurrence too high
see “Performance data”
• Inlet or drain line clogged or blocked
• Excessive dirt in medium (valve clogged)
• Solenoid valve defective
see “Maintenance”
• Pipe frozen
• Installation not carried out properly
see “Installation”
The alarm is automatically cancelled when the malfunction has been eliminated.