Safety instructions
BEKOMAT® 31U
5
Danger!
Supply voltage!
There is the risk of an electric shock involving injury or death when coming into contact
with non-insulated components carrying supply voltage.
Measures:
•
During electric installations, all regulations in force need to be adhered to (e.g. VDE 0100 / IEC 60364).
•
When the control unit is open, service and installation works must only be undertaken when the
system is deactivated.
•
The removed control unit has no IP degree of protection.
•
All types of electrical works must be carried out by authorised and qualified personnel only.
Further safety instructions:
•
For installation and operation, the national regulations and safety codes in force
must also be adhered to.
•
Do not use the BEKOMAT
®
31U in hazardous areas.
•
Regarding the inlet screw joints, excessive tightening forces must be avoided.
This applies in particular to conical screw joints.
•
The BEKOMAT
®
31U will only function when voltage is applied.
•
Do not use the test button for permanent drainage.
•
Use genuine spare parts only. This is imperative to ensure perfect functioning.
Additional advice:
•
The removed control unit has
no IP degree of protection
.
•
During installation, use spanner flat at the feed pipe (wrenchsize SW27) as a back rest.
•
The service unit must not be dismantled.
Caution!
Malfunction during operation!
Through incorrect installation and poor maintenance, malfunction may occur at the
BEKOMAT
®
.
Condensate which is not discharged may cause damage to plants and in production
processes.
r
Measures:
•
Condensate drainage which is reliable in performance directly optimises the compressed-air quality.
•
To prevent damage and breakdowns, it is imperative to observe the following:
•
Exact compliance with the specifications of use and with the performance parameters of
the BEKOMAT
®
, in connection with the case of application (see "Proper use" section)
•
Exact compliance with the installation- and operation instructions in this manual
•
Regular maintenance and control of the BEKOMAT
®
in accordance with the instructions
in this operating manual