![Beko BEKOMAT 31U Instructions For Installation And Operation Manual Download Page 7](http://html.mh-extra.com/html/beko/bekomat-31u/bekomat-31u_instructions-for-installation-and-operation-manual_31611007.webp)
Technical data
BEKOMAT® 31U
7
5 Technical data
min./max. operating pressure
0,8...16 bar (12...230 psi)
min./max. temperature
+1...+70 °C (+34...+158 °F)
Condensate inflow
G ½ (NPT ½) internal
max. screw-in depth 13,5 mm (½")
Condensate outflow
G ¼ Ø 8 ... 10 mm hose connector
Condensate
oil-contam oil-free
Housing
alu plastic, glass fibre-reinforced
Weight (empty)
0.8 kg (1.8 lbs)
This product has been tested to the requirements of CAN/CSA-C22.2 No. 61010-1-12, third edition, inclu-
ding a later version of the same standard incorporating the same level of testing requirements.
Max. performance for the "blue" climate zone – see also Chapter "Climate zones and performance data"
max. compressor performance
2.5 m³/min (87.5 scfm)
max. refrig.-dryer performance
5 m³/min (175 scfm)
max. filter performance
25 m³/min (875 scfm)