Wrong
Right
Description / explanation
Deflecting surface!
In the case of direct drainage from the compressed gas
line a deflection of the compressed gas flow is necessary!
Continuous slope!
If a pressure hose is used for inflow, avoid the formation
of a water pocket!
Continuous slope!
When laying pipes for the feed line, avoid the formation of
a water pocket.
Continuous slope!
Lay the condensate inlet line with a continuous slope! If
the installation height is limited, mount the lower inlet
with a separate venting line.
Ensure sufficient venting!
Large condensate quantities require installation of a
separate venting line.
Note the minimum height of installation!
The height of the condensate inlet must be located lower
than the lowest point of the collecting tank (e.g. vessel).
BEKOMAT
®
13, 13 CO, 13 CO PN25, 13 CO PN40
Original installation and operation manual
22 | 64