27 / 172 EN
Split Type Air Conditioner / User Manual
C
In North America, please choose
the right cable size according to
the Minimum Circuit Ampacity
indicated on the nameplate of
the unit.
1. Open front panel of the indoor unit.
2. Using a screwdriver, open the wire box cover
on the right side of the unit. This will reveal the
terminal block.
Terminal block
Wire cover
Screw
Cable clamp
Terminal block
Wire cover
Screw
Cable clamp
A
WARNING!
All wiring must be
performed strictly in accordance
with the wiring diagram located
on the back of the indoor units
front panel.
3. Unscrew the cable clamp below the terminal
block and place it to the side.
4. Facing the back of the unit, remove the plastic
panel on the bottom left-hand side.
5. Feed the signal wire through this slot, from the
back of the unit to the front.
6. Facing the front of the unit, connect the wire
according to the indoor unit’s wiring diagram,
connect the u-lug and firmly screw each wire to
its corresponding terminal.
A
CAUTION!
Do not mix up live and
null wires. This is dangerous, and
can cause the air conditioning
unit to malfunction.
7. After checking to make sure every connection is
secure, use the cable clamp to fasten the signal
cable to the unit. Screw the cable clamp down
tightly.
8. Replace the wire cover on the front of the unit,
and the plastic panel on the back.
C
The wiring connection process
may differ slightly between units
and regions.
Step 7: Wrappiping and cables
Before passing the piping, drain hose, and the
signal cable through the wall hole, you must
bundle them together to save space, protect
them, and insulate them (Not applicable in North
America).
1. Bundle the drain hose, refrigerant pipes, and
signal cable as shown below:
Indoor Unit
Space behind unit
Refrigerant piping
Drain hose
Signal wire
Insulation tape
Indoor Unit
Space behind unit
Refrigerant piping
Insulation tape
Drain hose
Signal wire
4 Installation
Summary of Contents for BEHPH 090
Page 2: ...ENGLISH 3 56 ITALIANO 57 114 FRANÇAIS 115 172 CONTENTS V2110002 AB UM ...
Page 172: ...Arçelik A Ş Karaağaç Caddesi No 2 6 34445 Sütlüce İstanbul Türkiye www beko com ...
Page 173: ...User Manual 10M 8505543200 4921 01 EN IT FR Remote Control ...
Page 174: ...ENGLISH 3 19 ITALIANO 20 37 FRANÇAIS 38 56 CONTENTS V2110002 AB RC ...
Page 228: ...Arçelik A Ş Karaağaç Caddesi No 2 6 34445 Sütlüce İstanbul Türkiye www beko com ...