8 / 172 EN
Split Type Air Conditioner / User Manual
•
If connecting power to fixed
wiring, an all-pole disconnection
device which has at least 3mm
clearances in all poles, and
have a leakage current that
may exceed 10mA, the residual
current device (RCD) having
a rated residual operating
current not exceeding 30mA,
and disconnection must be
incorporated in the fixed wiring
in accordance with the wiring
rules.
Take note of fuse
specifications
The air conditioner’s circuit board
(PCB) is designed with a fuse to
provide overcurrent protection. The
specifications of the fuse are printed
on the circuit board, such as:
T3.15AL/250VAC, T5AL/250VAC,
T3.15A/250VAC, T5A/250VAC,
T20A/250VAC, T30A/250VAC, etc.
C
Note:
For the units using R32
or R290 refrigerant, only the
blast-proof ceramic fuse can
be used.
Warnings for product
installation
1. Installation must be
performed by an authorized
dealer or specialist. Defective
installation can cause water
leakage, electrical shock, or
fire.
2. Installation must be performed
according to the installation
instructions. Improper
installation can cause water
leakage, electrical shock, or
fire.
3. Contact an authorized service
technician for repair or
maintenance of this unit. This
appliance shall be installed
in accordance with national
wiring regulations.
4. Only use the included
accessories, parts, and
specified parts for installation.
Using non-standard parts
can cause water leakage,
electrical shock, fire, and can
cause the unit to fail.
1 Safety Precautions
Summary of Contents for BEHPH 090
Page 2: ...ENGLISH 3 56 ITALIANO 57 114 FRANÇAIS 115 172 CONTENTS V2110002 AB UM ...
Page 172: ...Arçelik A Ş Karaağaç Caddesi No 2 6 34445 Sütlüce İstanbul Türkiye www beko com ...
Page 173: ...User Manual 10M 8505543200 4921 01 EN IT FR Remote Control ...
Page 174: ...ENGLISH 3 19 ITALIANO 20 37 FRANÇAIS 38 56 CONTENTS V2110002 AB RC ...
Page 228: ...Arçelik A Ş Karaağaç Caddesi No 2 6 34445 Sütlüce İstanbul Türkiye www beko com ...